• Anesthesia and analgesia · Jan 2006

    Comparative Study

    A comparison of state and response entropy versus bispectral index values during the perioperative period.

    • Paul F White, Jun Tang, Gladys F Romero, Ronald H Wender, Robert Naruse, Alexander Sloninsky, and Robert Kariger.
    • Department of Anesthesiology and Pain Management, University of Texas, Southwestern Medical Center at Dallas, Texas 75390-9068, USA. paul.white@utsouthwestern.edu
    • Anesth. Analg. 2006 Jan 1;102(1):160-7.

    AbstractCerebral monitoring indices are associated with a large degree of inter-patient variability and electrical signal interference during surgery. We designed this clinical study to test the hypothesis that use of the spectral entropy (Entropy) module is associated with less frequent intraoperative interference with the displayed indices than the bispectral index (BIS) monitor when used during general anesthesia with propofol and desflurane. Thirty consenting patients scheduled for major laparoscopic surgery procedures were enrolled in this prospective study. The elapsed time to obtain a baseline index value was recorded, as well as the simultaneous state entropy (SE), response entropy (RE), and BIS values at specific time intervals during the induction, maintenance, and emergence periods in patients administered a standardized general anesthetic technique. During the maintenance period, the changes in these indices were evaluated after a bolus dose of propofol (20 mg IV) and a 2% increase or decrease in the inspired concentration of desflurane. As expected, the baseline SE values were less than the RE and BIS values (88 +/- 2 versus 96 +/- 3 and 96 +/- 4, respectively). However, the SE and RE values correlated with the BIS value during the induction (r = 0.77 and 0.78, respectively) and emergence (r = 0.86 and 0.91, respectively) periods. The area under the receiver operating characteristic curve for detection of consciousness also indicated a similar performance of the SE (0.93 +/- 0.04) relative to the RE (0.98 +/- 0.04) and BIS (0.97 +/- 0.04). During the maintenance period, the responses to changes in propofol and desflurane concentrations were consistent with all three indices. Finally, the entropy indices were less interfered with by the electrocautery unit during the operation (12% versus 62% for the BIS monitor). Because the average selling prices of the Entropy and BIS disposable electrode strips (14.25 dollars versus 14.95 dollars USD, respectively) are comparable, we conclude that the Entropy module is a cost-equivalent alternative to the BIS monitor.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…