• Resuscitation · Nov 2013

    A new method to estimate the amplitude spectrum analysis of ventricular fibrillation during cardiopulmonary resuscitation.

    • Men-Tzung Lo, Lian-Yu Lin, Wan-Hsin Hsieh, Patrick Chow-In Ko, Yen-Bin Liu, Chen Lin, Yi-Chung Chang, Cheng-Yen Wang, Vincent Hsu-Wen Young, Wen-Chu Chiang, Jiunn-Lee Lin, Wen-Jone Chen, and Matthew Huei-Ming Ma.
    • Research Center for Adaptive Data Analysis & Center for Dynamical Biomarkers and Translational Medicine, National Central University, Taoyuan, Taiwan.
    • Resuscitation. 2013 Nov 1;84(11):1505-11.

    AimsAccurate ventricular fibrillation (VF) waveform analysis usually requires rescuers to discontinue cardiopulmonary resuscitation (CPR). However, prolonged "hands-off" time has a deleterious impact on the outcome. We developed a new filter technique that could clean the CPR artifacts and help preserve the shockability index of VF METHODS: We analyzed corrupted ECGs, which were constructed by randomly adding different scaled CPR artifacts to the VF waveforms. A newly developed algorithm was used to identify the CPR fluctuations. The algorithm contained two steps. First, decomposing the raw data by empirical mode decomposition (EMD) into several intrinsic mode fluctuations (IMFs) and combining the dominant IMFs to reconstruct a new signal. Second, calculating each CPR cycle frequency from the new signal and fitting the new signal to the original corrupted ECG by least square mean (LSM) method to derive the CPR artifacts. The estimated VF waveform was derived by subtraction of the CPR artifacts from the corrupted ECG. We then performed amplitude spectrum analysis (AMSA) for original VF, corrupted ECG and estimated VF.ResultsA total of 150 OHCA subjects with initial VF rhythm were included for analysis. Ten CPR artifacts signals were used to construct corrupted ECG. Even though the correlations of AMSA between the corrupted ECG vs. the original VF and the estimated VF vs. the original VF are all high (all p<0.001), the values of AMSA were obviously biased in corrupted ECG with wide limits of agreement in Bland-Altman mean-difference plot. ROC analysis of the AMSA in the prediction of defibrillation success showed that the new algorithm could preserve the cut-off AMSA value for CPR artifacts with power ratio to VF from 0 to 6 dB.ConclusionThe new algorithm could efficiently filter the CPR-related artifacts of the VF ECG and preserve the shockability index of the original VF waveform.Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…