• Spine · Apr 2002

    Advantage of pedicle screw fixation directed into the apex of the sacral promontory over bicortical fixation: a biomechanical analysis.

    • Ronald A Lehman, Timothy R Kuklo, Philip J Belmont, Romney C Andersen, and David W Polly.
    • Department of Orthopaedic Surgery and Rehabilitation, Walter Reed Army Medical Center, Washington, DC, USA.
    • Spine. 2002 Apr 15;27(8):806-11.

    Study DesignA biomechanical study of human cadaveric sacra using insertional torque and bone mineral density was conducted to determine the optimal sagittal trajectory of S1 pedicle screws.ObjectiveTo measure the maximal insertional torque of sacral promontory versus bicortical pedicle screw fixation.Summary Of Background DataFixation of instrumentation to the sacrum is commonly accomplished using S1 pedicle screws, with previous studies reporting biomechanical advantages of bicortical over unicortical S1 screws. The biomechanical effect of bicortical screws (paralleling the endplate) versus screws directed into the apex of the sacral promontory is unknown.MethodsFor this study, 10 fresh frozen cadaver sacra were harvested and evaluated with dual-energy radiograph absorptiometry to assess bone mineral density. Matched 7.5-mm monoaxial stainless steel pedicle screws then were randomly assigned by side (left versus right) and placed bicortically or into the apex of the sacral promontory under direct visualization. Maximum insertional torque was recorded for each screw revolution with a digital torque wrench (TQJE1500, Snap-On Tools, Kenosha, WI).ResultsMaximum bicortical S1 screw insertional torque averaged 5.22 +/- 0.83 inch-pounds, as compared with the maximum sacral promontory S1 screw insertional torque of 10.34 +/- 1.94 inch-pounds. This resulted in a 99% increase in maximum insertional torque (P = 0.005) using the "tricortical" technique, with the screw directed into the sacral promontory. Mean bone mineral density was 940 +/- 0.25 mg/cm2 (range, 507-1428 mg/cm2). The bone mineral density correlated with maximal insertional torque for the sacral promontory technique (r = 0.806; P = 0.005), but not for the bicortical technique (r = 0.48; P = 0.16).ConclusionsThe screws directed into the apex of the sacral promontory of the S1 pedicle resulted in an average 99% increase in peak insertional torque (P = 0.005), as compared with bicortical S1 pedicle screw fixation. Tricortical pedicle screw fixation correlates directly with bone mineral density.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.