    Diagnostic accuracy of the Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision aid with a point-of-care cardiac troponin assay.

    • Abdulrhman Alghamdi, Charles Reynard, Niall Morris, Phil Moss, Heather Jarman, Elaine Hardy, Tim Harris, Daniel Horner, Richard Parris, and Richard Body.
    • Division of Cardiovascular Sciences, The University of Manchester, Manchester, UK abdulrhman.alghamdi@mft.nhs.uk.
    • Emerg Med J. 2020 Apr 1; 37 (4): 223-228.

    ObjectivePoint-of-care (POC) cardiac troponin (cTn) assays have a rapid turnaround time but are generally less sensitive than laboratory-based assays. Previous research found that the Abbott i-Stat cardiac troponin I (cTnI) assay has good diagnostic accuracy when used with the Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision aid and serial sampling over 3 hours. Accuracy of other assays may differ. We therefore evaluated the diagnostic accuracy of a different POC cTnI assay with serial sampling over 3 hours, both with T-MACS and when used alone.MethodsIn a prospective diagnostic accuracy study at eight EDs in England (July 2015-October 2017), we collected clinical data from consenting adults with suspected ACS at the time of assessment in the ED. Blood samples were drawn on arrival and 3 hours later for POC cTnI (Cardio 3 Triage, Alere). The target condition was an adjudicated diagnosis of acute myocardial infarction (AMI), based on reference standard serial laboratory-based cTn testing. We calculated test characteristics for POC cTnI using the limit of detection (LoD, 0.01 µg/L) and the T-MACS decision aid.ResultsOf 347 participants, 59 (14.9%) had AMI. With serial POC cTnI testing over 3 hours, POC cTnI at the LoD cut-off ruled out AMI in 193 (55.6%) patients with 98.1% sensitivity (95% CI 89.9% to 100.0%) and 99.5% negative predictive value (NPV, 95% CI 96.5% to 99.9%). T-MACS ruled out AMI in 117 (33.7%) patients with 98.1% sensitivity (95% CI 89.9% to 100%) and 99.2% NPV (95% CI 94.3% to 99.9%). T-MACS ruled in AMI with 97.9% specificity (95% CI 95.8% to 99.5%) and 83.7% positive predictive value (95% CI 70.6% to 91.7%).ConclusionsWith serial sampling over 3 hours, the Alere Cardio 3 Triage cTnI assay has relatively high NPV for AMI using either the LoD cut-off alone or the T-MACS decision aid. However, wide CIs around the measures of diagnostic accuracy mean that further prospective testing of this strategy is required before clinical implementation.Trial Registration NumberUKCRN 18000.© Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…