Anesthesia and analgesia
-
Anesthesia and analgesia · Feb 2018
In Vitro Evaluation of a Novel Image Processing Device to Estimate Surgical Blood Loss in Suction Canisters.
Clinicians are tasked with monitoring surgical blood loss. Unfortunately, there is no reliable method available to assure an accurate result. Most blood lost during surgery ends up on surgical sponges and within suction canisters. A novel Food and Drug Administration-cleared device (Triton system; Gauss Surgical, Inc, Los Altos, CA) to measure the amount of blood present on sponges using computer image analysis has been previously described. This study reports on performance of a complementary Food and Drug Administration-cleared device (Triton Canister System; Gauss Surgical, Inc, Los Altos, CA) that uses similar image analysis to measure the amount of blood in suction canisters. ⋯ The Triton Canister System was able to measure the Hb mass reliably with clinically acceptable accuracy in reconstituted blood samples representing a wide range of Hb concentrations, dilutions, hemolysis, and ambient lighting settings.
-
Anesthesia and analgesia · Feb 2018
The Analgesic Effect of Ultrasound-Guided Quadratus Lumborum Block After Cesarean Delivery: A Randomized Clinical Trial.
Landmark and ultrasound-guided transversus abdominis plane blocks have demonstrated an opioid-sparing effect postoperatively after cesarean delivery. The more posterior quadratus lumborum (QL) might provide superior local anesthetic spread to the thoracolumbar fascia and paravertebral space. The aim of our study was to evaluate the efficacy of the QL block after cesarean delivery. ⋯ QL block with ropivacaine reduces the postoperative ketobemidone consumption and pain intensity as a part of a multimodal analgesic regimen that excludes neuraxial morphine.
-
Anesthesia and analgesia · Feb 2018
Randomized Controlled Trial Comparative StudyLabor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial.
Lumbar epidurals (LEs) provide excellent analgesia. Combined spinal epidural and dural puncture epidural (DPE) are 2 techniques to expedite neuraxial analgesia onset. In DPE, dura is punctured but medication is not administered in the cerebrospinal fluid. Expedited analgesia onset has been demonstrated with DPE, using 0.25% bupivacaine; however, this concentration may impede an unassisted vaginal birth and is not currently used for induction and maintenance of labor analgesia. The primary goal of this study was to compare the percentage of patients who achieved adequate labor analgesia following DPE or LE with an epidural bolus of 0.125% bupivacaine. Adequate labor analgesia was defined as Visual Analog Scale (VAS) measurement ≤ 10 mm on a 100-mm scale during active contractions, measured 10 minutes after epidural bolus initiation. ⋯ Although the percentage of parturients achieving adequate labor analgesia at 10 minutes after epidural bolus did not differ by technique, DPE was associated with faster time to VAS ≤ 10 mm compared with LE.
-
Anesthesia and analgesia · Feb 2018
Multicenter StudyManagement of 1-Lung Ventilation-Variation and Trends in Clinical Practice: A Report From the Multicenter Perioperative Outcomes Group.
Lung-protective ventilation (LPV) has been demonstrated to improve clinical outcomes in surgical patients. There are very limited data on the current use of LPV for patients undergoing 1-lung ventilation (1LV) despite evidence that 1LV may be a particularly important setting for its use. In this multicenter study, we report trends in ventilation practice for patients undergoing 1LV. ⋯ Despite a growing awareness of the importance of protective ventilation, a large proportion of patients undergoing 1LV continue to receive VT PEEP levels outside of recommended thresholds. Moreover, VT remains higher and LPV less common in high-risk subgroups, potentially placing them at elevated risk for iatrogenic lung injury.