The Annals of thoracic surgery
-
Randomized Controlled Trial Multicenter Study Comparative Study Clinical Trial
Left ventricular assist device performance with long-term circulatory support: lessons from the REMATCH trial.
Left ventricular assist device (LVAD) failure and malfunction rates are critical gauges for establishing LVADs as a long-term therapy for end-stage heart failure patients. These device performance measures, however, have been inadequately characterized in the bridge-to-transplantation literature. ⋯ Despite the observed rates of device malfunction and replacement, LVAD implantation confers clinically significant improvement with regard to survival as compared with medical management. Device modifications and innovations for infection management exhibit great promise of improving device performance in the near future.
-
Randomized Controlled Trial Comparative Study Clinical Trial
A closed perfusion system with heparin coating and centrifugal pump improves cardiopulmonary bypass biocompatibility in elderly patients.
Cardiopulmonary bypass induces a systemic inflammatory and hemostatic activation, which may contribute to postoperative complications. Our aim was to compare the inflammatory response, coagulation, and fibrinolytic activation between two different perfusion systems: one theoretically more biocompatible with a closed-circuit, complete heparin coating, and a centrifugal pump, and one conventional system with uncoated circuit, roller pump, and a hard-shell venous reservoir. ⋯ The results suggest that a closed perfusion system with a heparin-coated circuit and a centrifugal pump may improve cardiopulmonary bypass biocompatibility in elderly cardiac surgery patients in comparison with a conventional system.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Hemodynamic changes during posterior vessel off-pump coronary artery bypass: comparison between deep pericardial sutures and vacuum-assisted apical suction device.
Displacement of the heart to expose posterior vessels during off-pump coronary artery bypass may cause hemodynamic derangement. The aims of this study were (1) to elucidate the hemodynamic changes during off-pump coronary artery bypass for the obtuse marginal branch (OM) of the left circumflex artery; and (2) to compare the hemodynamic changes caused by a deep pericardial suture technique with those caused by a vacuum-assisted apical suction device for displacement of the heart. ⋯ Displacement of the heart using either a deep pericardial suture technique or a vacuum-assisted apical suction device caused a significant decrease in SVI. The hemodynamic changes during OM grafting were smaller when using a vacuum-assisted apical suction device.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Feasibility and results of awake thoracoscopic resection of solitary pulmonary nodules.
General anesthesia with single-lung ventilation is considered mandatory for thoracoscopic pulmonary resection. We assessed in a randomized study the feasibility and results of awake thoracoscopic resection of solitary pulmonary nodules. ⋯ In our study, awake thoracoscopic resection of solitary pulmonary nodules proved safely feasible. It resulted in better patient satisfaction, less nursing care and shorter in-hospital stay than procedures performed under general anesthesia.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Papaverine delivery to the internal mammary artery pedicle effectively treats spasm.
Left internal mammary artery spasm is well recognized during coronary artery bypass operations. Papaverine has been used by many surgeons to maximize mammary artery flow perioperatively, but the best delivery method is not known. We analyzed two techniques used at our institution. ⋯ Papaverine delivery to the left internal mammary artery after dissection treats spasm effectively, improves blood flow at the time of its anastamosis to the left anterior descending artery, and avoids any risk of intimal injury. Injection of papaverine before mammary artery harvest does not shorten dissection time, and flow is not statistically improved.