Annals of emergency medicine
-
Numerous investigators have evaluated the ECG algorithm described by Sgarbossa et al to predict acute myocardial infarction in the presence of left bundle branch block and have arrived at divergent conclusions. To clarify the utility of the Sgarbossa ECG algorithm, we perform a systematic review and meta-analysis of these trials. ⋯ A Sgarbossa ECG algorithm score of greater than or equal to 3, representing greater than or equal to 1 mm of concordant ST elevation or greater than or equal to 1 mm ST depression in leads V1 to V3, is useful for diagnosing acute myocardial infarction in patients who present with left bundle branch block on ECG. The scoring system demonstrates good to excellent overall interobserver variability. A score of 2, representing 5 mm or more of discordant ST deviation, demonstrated ineffective positive likelihood ratios. A Sgarbossa ECG algorithm score of 0 is not useful in excluding acute myocardial infarction.