Resuscitation
-
Randomized Controlled Trial Clinical Trial
The effect of differing support surfaces on the efficacy of chest compressions using a resuscitation manikin model.
External chest compression (ECC) efficacy is influenced by factors including the surface supporting the patient. Air-filled support surfaces are deflated for cardiopulmonary resuscitation, with little evidence to substantiate this. We investigated the effect that differing support surfaces had on ECC efficacy using a CPR manikin model. ⋯ The efficacy of ECC is affected by the support surfaces. There seems little evidence to substantiate deflating all air-filled support surfaces for CPR.