European journal of anaesthesiology
-
Randomized Controlled Trial Comparative Study
Lateral neck radiography for prediction of difficult orotracheal intubation.
Failed endotracheal intubation is a principal cause of morbidity and mortality in anesthetized patients. The aim of this study was to investigate the efficiency of lateral neck radiography in predicting difficult intubation. ⋯ Compared to the Mallampati Class test, our method of analyzing the lateral X-ray, although not as easy and universally applicable as Mallampati Class test, proved to be a suitable method for predicting difficult intubation.
-
Randomized Controlled Trial Comparative Study
Comparison of propofol-alfentanil and propofol-remifentanil anaesthesia in percutaneous nephrolithotripsy.
Percutaneous nephrolithotripsy (PCNL) is used for the fragmentation and removal of stones from the renal pelvis and renal calyceal systems. We compared the effects of propofol-alfentanil or propofol-remifentanil anaesthesia on haemodynamics, recovery characteristics and postoperative analgesic requirements during percutaneous nephrolithotripsy. ⋯ Both propofol-remifentanil and propofol-alfentanil anaesthesia provided stable haemodynamics during percutaneous nephrolithotripsy, whereas propofol-remifentanil allowed earlier extubation.
-
Randomized Controlled Trial Comparative Study
Haemodynamic changes induced by hyperbaric bupivacaine during lateral decubitus or supine spinal anaesthesia.
Hypotension, the commonest side-effect of spinal anaesthesia, results from sympathetic denervation. This study compared patient positioning (supine vs. decubitus) on haemodynamic variables during spinal anaesthesia. ⋯ Lateral positioning for spinal anaesthesia delays the onset of hypotension, while requiring smaller total doses of vasoconstrictors for blood pressure maintenance.
-
Comparative Study
Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients.
Accurate assessment of preload responsiveness is an important goal of the clinician to avoid deleterious volume replacement associated with increased morbidity and mortality in mechanically ventilated patients. This study was designed to evaluate the accuracy of simultaneously assessed stroke volume variation and pulse pressure variation using an improved algorithm for pulse contour analysis (PiCCO plus, V 5.2.2), compared to the respiratory changes in transoesophageal echo-derived aortic blood velocity (deltaVpeak), intrathoracic blood volume index, central venous pressure and pulmonary capillary wedge pressure to predict the response of stroke volume index to volume replacement in normoventilated cardiac surgical patients. ⋯ The results of our study suggest that stroke volume variation and its surrogate pulse pressure variation derived from pulse contour analysis using an improved algorithm can serve as indicators of fluid responsiveness in normoventilated cardiac surgical patients. Whenever changes in systemic vascular resistance are expected, the PiCCO plus system should be recalibrated.
-
Since the introduction of the laryngeal mask into clinical practice, various additional supraglottic ventilatory devices have been developed. Although it has been demonstrated that the laryngeal tube is an effective airway device during positive pressure ventilation no clinical study has been performed thus far regarding its use in patients with predicted ventilation and intubation difficulties. ⋯ The possibility of difficult ventilation and intubation must always be considered, in patients with supraglottic airway tumours. In these cases, the laryngeal tube can be considered for routine airway management and may be useful in the 'cannot-intubate' situation although difficulties should be anticipated in patients with previous irradiation, specifically of the throat area.