Canadian journal of anaesthesia = Journal canadien d'anesthésie
-
We have examined the reliability of end-tidal carbon dioxide (PetCO2) monitoring as an estimate of arterial carbon dioxide tension (PaCO2) in spontaneously breathing infants and children. Forty patients were studied in the post-anaesthetic care unit; 20 < 12 kg and 20 > or = 12 kg. The PetCO2 was sampled via a 5 cm 16 gauge catheter taped below an external naris and this measurement was compared with the PaCO2 of a sample drawn from an indwelling arterial line. ⋯ Patients studied in the post-anaesthetic care unit showed good correlation between PetCO2 and PaCO2 regardless of weight: Pa-etCO2 of -0.6 +/- 3.6 (< 12 kg) and -1.1 +/- 2.8 mmHg (> or = 12 kg). Patients studied during mask anaesthesia showed better correlation between PetCO2 and PaCO2 when PetCO2 was sampled from the cannula: Pa-etCO2 of 3.5 +/- 4.8 mmHg (cannula), 8.6 +/- 4.5 (elbow) (P < 0.05). These results suggest that end-tidal CO2 monitoring is a useful and reliable method for assessing adequacy of ventilation in spontaneously breathing children weighing between 5.2 and 35 kg.
-
The purpose of this report is to describe a potentially hypoxic event which occurred during mask induction with the Bain circuit in a healthy. ASA I boy. Failure of induction occurred because a pop-off weight from a bubble bottle was lodged in the elbow connecting the Bain circuit to the mask and prevented gas flow. ⋯ Such an anaesthetic mishap could occur with any breathing circuit which is re-used. Although there was no serious misadventure, the potential for an hypoxic complication with either intra-venous induction of anaesthesia, or dislodging of the weight into the airway was significant. We conclude that the standard tests of system patency do not ensure safety.
-
A medication error caused a near fatal cardiac arrest in a previously healthy patient undergoing elective surgery. Inadvertent epinephrine injection induced ventricular dysrhythmias, hypertension, hypotension and pulmonary oedema. ⋯ These include: improved resident training in intravenous drug management, the use of anaesthetic drug ampoules with distinct labels, and the development of a standardized colour code system for labels on anaesthetic drug ampoules. Furthermore, it is recommended that all anaesthetic drug errors be reported to the Canadian agencies responsible for drug packaging in order to identify patterns in anaesthetic drug errors, and to facilitate the implementation of effective drug identification systems.
-
Randomized Controlled Trial Clinical Trial
Mask lung ventilation by ambulance personnel: a performance assessment.
We evaluated the ability of basic life support ambulance officers and anaesthetists to perform lung ventilation with a face mask. After induction of anaesthesia and institution of standardized airway conditions the ambulance officer or anaesthetist placed a mask on the patient's face and lung ventilation was commenced. The order of hand grip (one vs two hands) was randomized. ⋯ There was no difference in the mask leak when the professions were compared but ambulance officers had a lower mask leak with a two-handed grip at 20 cm H2O (P < 0.001). Anaesthetists had a greater incidence of gastro-oesophageal insufflation when a two-handed mask grip was utilized (P < 0.05). In healthy relaxed patients there appeared to be little difference between the ambulance officers and qualified anaesthetists in airway maintenance or mask-holding ability.
-
Comparative Study
Evoked potential monitoring during posterior fossa aneurysm surgery: a comparison of two modalities.
The purpose of this study was to compare and assess the ability of two different evoked potential (EP) modalities, median nerve somatosensory evoked potentials (SSEP) and brainstem auditory evoked potentials (BAEP) in monitoring for cerebral ischaemia and in predicting neurological outcome during posterior fossa aneurysm surgery. During 70 procedures, patients were monitored with both SSEP and BAEP. Temporary occlusion of an artery was used in 52 patients and permanent occlusion in 21 patients. ⋯ The incidence of false positive results (an EP change but no deficit) was 13% overall (SSEP 11%, BAEP 7%). All patients who had a permanent EP change developed a neurological deficit. We did not find a difference in the ability of SSEP compared with BAEP in predicting neurological deficits but, using both modalities, the incidence of false negative results was decreased.(ABSTRACT TRUNCATED AT 250 WORDS)