European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
-
Although the effect of physical workload on the occurrence of low back pain (LBP) has been extensively investigated, few quantitative studies have examined the morphological changes visualized via magnetic resonance imaging (MRI) in relation to occupational variables. The relationship between the severity of some abnormalities such as lumbar spinal stenosis or spondylolisthesis and physical or psychosocial occupational risk factors has not been investigated previously. In this cross-sectional study patients fulfilled the following inclusion criteria: (1) long-standing (minimum 1-year) LBP radiating down the leg (or not); (2) age more than 40 years; (3) willingness to undergo an MRI of the lumbar spine; and (4) ability to speak Italian. ⋯ A heavier job workload was the only occupational factor positively related to the degree of disability at the multivariate analysis (P=0.002). Total amount of degeneration in the lumbar spine directly influenced pain duration (P=0.011) and degree of disability (P=0.050). These results suggest that caution should be exercised when symptomatic subjects with evidence of degenerative changes on MRI scans engage in strenuous physical labor.
-
Comparative Study Controlled Clinical Trial
Validity of pressure pain thresholds in female workers with and without recurrent low back pain.
Recurrent low back pain (LBP) is a common pain condition in elderly workers in a variety of occupations, but little is known about its origin and the mechanisms leading to an often disabling sensation of pain that may be persistent or intermittent. In the present study we evaluated the pressure pain thresholds (PPTs) in subjects suffering from recurrent LBP, as well as in healthy controls, to investigate if recurrent LBP is associated with an increased sensitivity of the muscular and ligamentous structures located on the lower back. One hundred and six female workers, aged between 45 and 62 years and working either in administrative or nursing professions were examined. ⋯ The PPT on the lower back did not significantly differ between the four groups studied, namely nurses and administrative workers with and without recurrent LBP. These results give evidence that recurrent LBP is not associated with an altered sensitivity of the muscular and myofascial tissues in the lumbar region. Furthermore, they raise questions about the value of reference point measurements in recurrent LBP.
-
Clinical Trial
Anterior vertebral body replacement with a titanium implant of adjustable height: a prospective clinical study.
In the operative treatment of spinal injuries, the reconstruction of the anterior column of the thoracolumbar spine is still controversial. We conducted a prospective clinical study to investigate the clinical and radiological outcome of 50 patients treated with a vertebral body replacement of adjustable height (Synex). Fifty consecutive patients were evaluated during in-patient treatment and at 12 and 20 months post-operatively in clinical notes and radiographs. 38/50 patients were operated for traumatic fractures. ⋯ The loss of correction or reduction was only minimal. On the basis of our results we recommend the Synex implant as an alternative for the fixation and stabilisation of thoracolumbar fractures. However, long-term results and a clinically random control study are still required.
-
Randomized Controlled Trial Comparative Study
Assessment of CAOS as a training model in spinal surgery: a randomised study.
The objectives of this study were (1) to quantify the benefit of computer assisted orthopaedic surgery (CAOS) pedicle screw insertion in a porcine cadaver model evaluated by dissection and computed tomography (CT); (2) to compare the effect on performance of four surgeons with no experience of CAOS, and varying experience of pedicle screw insertion; (3) to see if CT with extended windows was an acceptable method to evaluate the position of the pedicle screws in the porcine cadaver model, compared to dissection. This was a prospective, randomised, controlled and blinded porcine cadaver study. Twelve 6-month-old porcine (white skinned Landrace) lumbar spines were scanned pre-operatively by spiral CT, as required for the CAOS computer data set. ⋯ The experienced general orthopaedic surgeon did not benefit from CAOS (P = 0.5). CT compared to dissection showed an intra-observer reliability of 99.4% and inter-observer reliability of 92.6%. The conclusions of this study were as follows: (1) an increased number of pedicle screws were ideally placed using the CAOS electromagnetic guidance system compared to the conventional freehand technique; (2) junior surgeons benefited most from CAOS; (3) we believe CAOS (Navitrak) with porcine lumbar spines evaluated by post operative CT, represents a useful model for training junior surgeons in pedicle screw placement; (4) experienced spine surgeons, who have never used CAOS, may find CAOS less helpful than previously reported.
-
Comparative Study Clinical Trial
Role of transarticular screw fixation in tuberculous atlanto-axial instability.
Prospective study of 27 consecutive cases of tuberculous atlanto-axial instability operated between 1998 and 2003. Early surgical stabilization of tuberculous atlanto-axial instability has gained popularity. This is largely due to success of chemotherapy in rapid control of infection. ⋯ Results in 27 consecutive patients demonstrate improved patient fusion and satisfaction rates in the TAS group. Judicious selection of patients for TAS fixation is possible with relatively few complications in tuberculosis of the atlanto-axial complex. This, however, requires a thorough understanding of the MRI pattern of involvement of the atlanto-axial complex that is difficult in non-endemic areas.