Anaesthesia
-
Randomized Controlled Trial Comparative Study
The circulatory responses to fibreoptic intubation: a comparison of oral and nasal routes.
The circulatory responses to fibreoptic intubation under general anaesthesia were studied in 60 adult female patients who were randomly assigned to receive either the oral or nasal route for insertion. Non-invasive blood pressure and heart rate were recorded before anaesthesia induction (baseline values), immediately after anaesthesia induction (post-induction values), at intubation and every minute for a further 5 min. The product of heart rate and systolic blood pressure (rate pressure product) at every time point was also calculated. ⋯ There were no significant differences between the two groups in blood pressure, heart rate and rate pressure product at any measuring point, or in the maximum values during observation. The time required for recovery of systolic blood pressure to the post-induction value was not significantly different between the two groups, but the time required for recovery of heart rate to post-induction value was significantly longer in the fibreoptic orotracheal intubation group than in the fibreoptic nasotracheal intubation group. It was concluded that both fibreoptic orotracheal and fibreoptic nasotracheal intubations could cause a similar magnitude of circulatory responses in general anaesthetised, female adults, but the tachycardic response to fibreoptic orotracheal intubation lasted longer than that to fibreoptic nasotracheal intubation.
-
At the First International Symposium on the History of Modern Anaesthesia (1982), Professor Keuskamp mentioned that the introduction of breathing machines for lung ventilation during operations had taken over 'the tiresome handwork of ventilation'. This paper traces some aspects of Keuskamp's professional career and his role in the development of the Amsterdam Infant Ventilator. ⋯ Other clinicians from the United States and Europe echoed this satisfactory clinical evaluation. At present, this paediatric ventilator is still in use for the initial ventilation of small infants and for the mechanical ventilation of different animal species in a variety of experimental settings.
-
This study examines the incidence and site of tracheal tube impingement during nasotracheal fibreoptic intubation, and the efficacy of anticlockwise tube rotation to overcome the problem. Forty-three patients underwent fibreoptic-assisted nasotracheal intubation using a preformed nasal tube, and a second fibrescope was used to observe any obstruction to passage of the tracheal tube. ⋯ Rotation resulted in successful intubation in all 10 cases, but proximal rotation did not always result in an equal degree of rotation at the tube tip. We conclude that the site of impingement for nasotracheal intubation with preformed nasal tubes is located at the posterior structures of the laryngeal inlet and that anticlockwise rotation is a simple and effective solution.