Anaesthesia
-
Randomized Controlled Trial Comparative Study
A comparison of the pelvic angle applied using lateral table tilt or a pelvic wedge at elective caesarean section.
Lateral table tilt or a pelvic wedge are commonly used to reduce inferior vena cava compression during obstetric anaesthesia in the supine position. Direct measurement of pelvic angle allows individual assessment of the effectiveness of these manoeuvres in achieving a tilted position. We observed routine practice during caesarean section after random allocation to one or other of these methods. ⋯ There was a significant difference between table angle and pelvic angle in the women with table tilt (p = 0.0003), but no significant difference in pelvic angle between the table tilt and wedge groups. Measurement of table angle does not represent pelvic position adequately in the majority of women. However, this study showed that lateral table tilt and a pelvic wedge were equally effective in producing tilt of the pelvis.
-
Review Case Reports
Case report and literature review of chronic neuropathic pain associated with peripheral venous cannulation.
We report a case of neuropathic pain following peripheral venous cannulation for an elective surgical procedure and discuss the various mechanisms by which this could occur. The mostly likely trigger in this case is phlebitis as the onset of symptoms coincided with the local infection. Neuropathic pain can occur following innocent interventions and its impact on the patient's quality of life may be reduced by timely recognition and management.
-
The aim of this prospective clinical study was to evaluate the location of paravertebral catheters that were placed using the classical landmark puncture technique and to correlate the distribution of contrast dye injected through the catheters with the extent of somatic block. Paravertebral catheter placement was attempted in 31 patients after video-assisted thoracic surgery. In one patient, an ultrasound-guided approach was chosen after failed catheter placement using the landmark method. ⋯ There was also a discrepancy between the radiological findings and the observed distribution of loss of sensation. We have demonstrated an unacceptably high misplacement rate of paravertebral catheters using the landmark method. Additional research is required to compare the efficacy and safety of continuous paravertebral block using ultrasound-guided techniques or surgical inserted catheters.
-
Randomized Controlled Trial Comparative Study
A randomised crossover trial comparing a single-use polyvinyl chloride laryngeal mask airway with a single-use silicone laryngeal mask airway.
We compared insertion rates of single-use polyvinyl chloride laryngeal mask airways (LMAs) vs single-use silicone LMAs in 72 anaesthetised patients. Both airways were produced by Flexicare Medical. Laryngeal mask airway insertion was successful on the first attempt in 68/72 (94%) polyvinyl chloride LMAs vs 64/72 (89%) silicone LMAs (p = 0.39). ⋯ Laryngeal mask airway position, as assessed using a fibrescope, was not different (p = 0.077). The median (IQR [range]) leak pressure was 16 (12-20 [6-30]) cmH(2) O for the polyvinyl LMA and 18 (13-22 [6-30]) cmH(2) O or the silicone LMA (p = 0.037). In conclusion, we did not find any important differences between polyvinyl chloride and silicone laryngeal mask airways.