Anaesthesia
-
The dye indocyanine green is familiar to anaesthetists, and has been studied for more than half a century for cardiovascular and hepatic function monitoring. It is still, however, not yet in routine clinical use in anaesthesia and critical care, at least in Europe. This review is intended to provide a critical analysis of the available evidence concerning the indications for clinical measurement of indocyanine green elimination as a diagnostic and prognostic tool in two areas: its role in peri-operative liver function monitoring during major hepatic resection and liver transplantation; and its role in critically ill patients on the intensive care unit, where it is used for prediction of mortality, and for assessment of the severity of acute liver failure or that of intra-abdominal hypertension. Although numerous studies have demonstrated that indocyanine green elimination measurements in these patient populations can provide diagnostic or prognostic information to the clinician, 'hard' evidence - i.e. high-quality prospective randomised controlled trials - is lacking, and therefore it is not yet time to give a green light for use of indocyanine green in routine clinical practice.
-
Comparative Study
A comparison of airway dimensions, measured by acoustic reflectometry and ultrasound before and after general anaesthesia.
Changes in airway dimensions can occur during general anaesthesia and surgery for a variety of reasons. This study explored factors associated with postoperative changes in airway dimensions. Patient airway volume was measured by acoustic reflectometory and neck muscle diameter by ultrasound echography in the pre- and post-anaesthetic periods in a total of 281 patients. ⋯ A significant decrease in median (IQR [range]) total airway volume (from 63.8 (51.8-75.7 [14.7-103]) ml to 45.9 (33.5-57.2 [6.4-96.3]) ml, p < 0.0001), and a significant increase in muscle diameter (from 4.3 (3.3-5.6 [2.2-9.0]) mm to 5.8 (4.7-7.3 [2.8-1.3]) mm, p < 0.0001) and neck circumference (from 34.0 (32.5-37.0 [29.5-49.0]) cm to 35.0 (33.5-38.0 [30.5-50.5]) cm, p < 0.0001) were observed. It may be possible that changes in airway volume and neck circumference were influenced by surgical duration or peri-operative fluid management (ρ) = -0.31 (95% CI -0.24 to -0.01), p = 0.0301, -0.17 (-0.23 to -0.06), p = 0.0038, 0.23 (0.12-0.34), p < 0.0001, and 0.16 (0.05-0.27), p = 0.0062, respectively). The intra-oral space can significantly decrease and neck thickness increase after general anaesthesia, and might increase the risk of difficult laryngoscopy and intubation if airway management is required after extubation following general anaesthesia.
-
A bench-top study was performed to assess the effects of different laryngoscope handles on the light intensity delivered from disposable metal or plastic laryngoscope blades. The light intensity from both the handle light sources themselves and the combined handle and laryngoscope blade sets was measured using a custom-designed testing system and light meter. ⋯ Overall, the 3.5 V Heine handle delivered the highest light output (p < 0.007) in comparison with the other handles. For the disposable blades, the overall light output was significantly higher from the plastic than the metal blades (p < 0.001).
-
Peripherally inserted central catheters are often positioned blindly in the central circulation, and this may result in high malposition rates, especially in critically ill patients. Recently, a new technology has been introduced (Sherlock 3CG Tip Positioning System) that uses an electro-magnetic system to guide positioning in the superior vena cava, and then intra-cavity ECG to guide positioning at the cavo-atrial junction. In this observational study, we investigated how the Sherlock 3CG Tip Positioning System would affect peripherally inserted central catheter malposition rates, defined using a post-insertion chest radiograph, in critically ill patients. ⋯ When an adequate position was defined as low superior vena cava or cavo-atrial junction, 134 catheters (56.1%; 95% CI 50-62%) were malpositioned. When an adequate position was defined as mid/low superior vena cava, cavo-atrial junction or high right atrium (≤ 2 cm from cavo-atrial junction), 49 (20.5%; 95% CI 16-26%) catheters were malpositioned. These malposition rates are significantly lower than our own historical data, which used a 'blind' anthropometric technique to guide peripherally inserted central catheter insertion.
-
During central neuraxial blockade, identifying the midline in parturients can be difficult, particularly if they are obese. We assessed the ability of women in late pregnancy, both obese and non-obese, to identify the midline of their own back by pointing and by pinprick discrimination with reference to the true midline identified by ultrasound. ⋯ Identification of the midline using pinprick was poorer by obese women (median (IQR [range]) 33 (25-45 [3-85]) mm) than by non-obese women (18 (13-25 [8-40]) mm; p < 0.0001). However, women in both groups were correct > 99% of the time in identifying that a stimulus was either to the left or to the right side.