Anaesthesia
-
Review Meta Analysis
Evidence for compromised data integrity in studies of liberal peri-operative inspired oxygen.
High intraoperative FiO2 does not significantly reduce surgical site infections.
pearl -
Review Meta Analysis
Analgesic impact of intra-operative opioids vs. opioid-free anaesthesia: a systematic review and meta-analysis.
Opioids are administered peri-operatively for postoperative analgesia, and intra-operatively to control the sympathetic response to surgical stimuli, frequently as a surrogate for presumed pain. However, opioid use during surgery is a matter of dispute in contemporary practice and carries the risk of side-effects such as postoperative nausea and vomiting. This meta-analysis investigated whether opioid-inclusive, compared with opioid-free anaesthesia, would reduce postoperative pain, without increasing the rate of postoperative nausea and vomiting. ⋯ Pain scores at rest at two postoperative hours were equivalent in the opioid-inclusive and opioid-free groups with a mean difference (95%CI) of 0.2 (-0.2 to 0.5), I2 = 83%, p = 0.38 and a high quality of evidence. Similarly, there was high-quality evidence that the rate of postoperative nausea and vomiting was reduced in the opioid-free group, with a risk ratio (95%CI) of 0.77 (0.61-0.97), I2 = 16%, p = 0.03 and high-quality evidence for a similar length of stay in the recovery area, the mean difference (95%CI) being 0.6 (-8.2 to 9.3), min, I2 = 60%, p = 0.90. As there is strong evidence that opioid-inclusive anaesthesia does not reduce postoperative pain, but is associated with more postoperative nausea and vomiting, when compared with opioid-free anaesthesia, we suggest that anaesthetists should reconsider their intra-operative opioid choices on a case-by-case basis.
-
Multicenter Study
Multicentre clinical simulation evaluation of the ISO 80369-6 neuraxial non-Luer connector.
To avoid potentially fatal wrong-route neuraxial drug errors, international standard ISO 80369-6 specifying a non-Luer neuraxial connector design was published in 2016. We describe usability studies used in development of the design. Thirty-eight doctors and 17 nurses performed simulated procedures on manikins, using devices fitted with Luer connectors or draft ISO 80369-6 'non-Luer' connectors. ⋯ Most cross-connection attempts failed, even using above clinical forces and, when successful, were judged of low clinical risk potential; the exception was a malaligned connection between the non-Luer slip and female Luer connectors. This led to revision of the dimensional tolerances of the non-Luer connector to reduce this risk, before publication of the final specification in 2016. We conclude that the ISO 80369-6 neuraxial non-Luer connector is suitable for clinical use.
-
Letter Practice Guideline
Guidelines for the safe provision of anaesthesia in magnetic resonance units 2019: Guidelines from the Association of Anaesthetists and the Neuro Anaesthesia and Critical Care Society of Great Britain and Ireland.
There has been an increase in the number of units providing anaesthesia for magnetic resonance imaging and the strength of magnetic resonance scanners, as well as the number of interventions and operations performed within the magnetic resonance environment. More devices and implants are now magnetic resonance imaging conditional, allowing scans to be undertaken in patients for whom this was previously not possible. There has also been a revision in terminology relating to magnetic resonance safety of devices. ⋯ They reinforce the safety aspects of providing anaesthesia in the magnetic resonance environment, from the multidisciplinary decision making process, the seniority of anaesthetist accompanying the patient, to training in the recognition of hazards of anaesthesia in the magnetic resonance environment. For many anaesthetists this is an unfamiliar site to give anaesthesia, often in a remote site. Hospitals should develop and audit governance procedures to ensure that anaesthetists of all grades are competent to deliver anaesthesia safely in this area.