Health technology assessment : HTA
-
Health Technol Assess · Jan 2003
Review Meta Analysis Comparative StudyThe clinical and cost-effectiveness of pulsatile machine perfusion versus cold storage of kidneys for transplantation retrieved from heart-beating and non-heart-beating donors.
To evaluate the clinical and cost-effectiveness of machine perfusion (MP) compared to cold storage (CS), as a means of preserving kidneys prior to transplantation. Transplantation of kidneys from both heart-beating donors (HBDs) and non-heart-beating donors (NHBDs) is considered. Finally to review whether the use of MP can allow valid testing of kidney viability prior to transplantation. ⋯ The baseline analysis indicated that in the long-term MP would be expected to be cheaper and more effective than CS for both HBD and NHBD recipients. A definitive study of the clinical benefit of MP in order to establish its effect on DGF and longer term graft survival would be valuable, together with an economic evaluation of the benefits. While direct evidence relating to improvements in graft survival would be preferable, the small predicted improvement indicates that a very large sample size would be required. In addition to seeking direct evidence of the impact on DGF, research quantifying the impact of DGF on graft survival in this technology is required. Research is also needed to establish whether a valid test (or combination of tests) of kidney viability can be developed.