British journal of anaesthesia
-
Case Reports
Repetitive paravertebral nerve block using a catheter technique for pain relief in post-herpetic neuralgia.
We described in this report a case of post-herpetic neuralgia refractory to medical therapy that was successfully treated with repetitive injections of local aesthetic mixture (bupivacaine 0.5% 19 ml and clonidine 150 microg ml(-1) 1 ml) every 48 h for 3 weeks using a paravertebral catheter inserted at T2-T3 level.
-
Direct indicators for the evaluation of the nociceptive-anti-nociceptive balance during general anaesthesia do not exist. The aim of this study was to combine physiological parameters to obtain such an indicator. ⋯ The empirically developed algorithm of RN leads to an index that seems to adequately estimate the nociceptive-anti-nociceptive balance at skin incision during general anaesthesia. In the future, CSSA may serve as a reference for studies investigating methods aimed at evaluating this pharmacodynamic component of anaesthesia.
-
During general anaesthesia in the presence of neuromuscular blocking drugs clinical criteria cannot detect the presence of consciousness. Various 'depth of anaesthesia' monitors are available which claim to prevent consciousness and/or reduce anaesthetic drug use. This study uses the Narcotrend anaesthesia brain monitor to guide anaesthetic administration but at the same time checks for the presence of intra-operative consciousness by using the 'isolated forearm' technique throughout the whole surgical/anaesthetic procedure. ⋯ The Narcotrend was unable to differentiate reliably between conscious and unconscious patients during general anaesthesia when neuromuscular blocking agents were used.
-
The predominant effect of opioids on respiratory pattern during anaesthesia is an increase in the duration of expiration (an effect on 'timing'), but there may also be changes in tidal volume (an effect on 'drive'). Timing and drive are controlled by separate neuronal systems, but are infrequently considered individually. The effects of opioids on breathing are not well characterized clinically because changes in carbon dioxide and anaesthetic levels usually occur at the same time, and can obscure the effects of the opioid. ⋯ Small doses of opioid given when anaesthesia and carbon dioxide are stable affect respiratory timing predominantly, but in addition changes in the pattern of motor output can be detected.
-
The LMA CTrach is a new laryngeal mask system consisting of an LMA CTrach Airway with integrated fibreoptic channels, and a detachable LMA CTrach Viewer. This system enables viewing of the larynx and aids endotracheal intubation through a laryngeal mask airway. Method. We used and evaluated this system in 100 adult patients undergoing general anaesthesia for elective surgery. Our primary outcomes were the success rates of LMA CTrach Airway insertion and endotracheal intubation with this system. ⋯ The LMA CTrach system has potential advantages over the LMA Fastrach system, including the ability to align the LMA outlet with the larynx and a high first intubation attempt success rate. However, it was difficult to view the larynx with the LMA CTrach compared with direct laryngoscopy, and expectations must be moderated.