Neuromodulation : journal of the International Neuromodulation Society
-
Randomized Controlled Trial
Brain Activity and Clinical Outcomes in Adults With Depression Treated With Synchronized Transcranial Magnetic Stimulation: An Exploratory Study.
Synchronized transcranial magnetic stimulation (sTMS) imparts low-amplitude magnetic stimulation matched to each patient's individual alpha frequency. It may act through entrainment of brain oscillations. ⋯ Neurophysiologic measures suggest that active but not sham sTMS engages brain targets, and that target engagement is related to treatment outcome.
-
Chronic pain (CP) affects a significant number of patients following hernia repair, ranging from 11 to 54% in the literature. The aim of this study was to assess the prevalence, overall costs, and health care utilization associated with CP after hernia repair. ⋯ Our study demonstrates the prevalence of CP after hernia surgery to be nearly 20%, with significantly increased costs and healthcare resource utilization. While current treatment paradigms are effective for many, there remains a large number of patients that could benefit from an overall approach that includes nonopioid treatments, such as potentially incorporating neurostimulation, for CP that presents posthernia repair.
-
Case Reports Comparative Study
Open Microsurgical Dorsal Root Ganglion Lead Placement.
Dorsal root ganglion stimulation (DRG) is a new but well-established neuromodulation technique allowing new indications and superiority to pre-existing stimulation techniques such as spinal cord stimulation in selected pain etiologies. Previous surgical procedures in the implantation area pose a challenge for the percutaneous technique and are therefore considered contraindications for DRG stimulation surgery. We describe the successful open DRG electrode placement in two patients with previous surgeries suffering from severe radiculopathy due to foraminal stenosis. ⋯ The option of open electrode placement should be taken into account following unsuccessful percutaneous lead placement. A combination of fibrin sealant patch and fibrin glue may be a good option for stabilization of the lead and specially of the strain relief loops in open placement. Knowledge of basic spinal surgery techniques and experience in percutaneous DRG stimulation is necessary to perform this procedure.
-
Non-invasive transcranial direct current stimulation (tDCS) over the motor cortex is broadly investigated to modulate functional outcomes such as motor function, sleep characteristics, or pain. The most common montages that use two large electrodes (25-35 cm2 ) placed over the area of motor cortex and contralateral supraorbital region (M1-SO montages) require precise measurements, usually using the 10-20 EEG system, which is cumbersome in clinics and not suitable for applications by patients at home. The objective was to develop and test novel headgear allowing for reproduction of the M1-SO montage without the 10-20 EEG measurements, neuronavigation, or TMS. ⋯ The novel approach to M1-SO montage using a fixed-angle headgear not requiring measurements by patients or caregivers facilitates tDCS studies in home settings and can replace cumbersome C3 measurements for clinical tDCS applications.