Journal of clinical monitoring and computing
-
J Clin Monit Comput · Oct 2021
Technical considerations when using the EEG export of the SEDLine Root device.
Electroencephalographic (EEG) patient monitoring during general anesthesia can help to assess the real-time neurophysiology of unconscious states. Some monitoring systems like the SEDLine Root allow export of the EEG to be used for retrospective analysis. We show that changes made to the SEDLine display during recording affected the recorded EEG. ⋯ Changing the display settings results in undocumented changes in EEG amplitude, sampling rate, and signal quality. The occult nature of these changes could make the analysis of data sets difficult if not invalid. We strongly suggest researchers adequately define and keep the EEG display settings to export good quality EEG and to ensure comparability among patients.
-
J Clin Monit Comput · Oct 2021
A new implementation of EN1839 method T mixture preparation to prepare calibration gas mixtures for anesthetic gas monitors.
In this study different mixtures from anesthetic liquids vapours in air and O2-sevoflurane/air, sevoflurane/O2 and isoflurane/O2-were prepared according to EN1839 method T. The gases mixtures were used to calibrate anesthetic gas monitors. The targeted concentrations (TCs) from sevoflurane and isoflurane in air and O2 were 0 vol%, 0.15 vol%, 0.7 vol%, 1 vol%, 1.5 vol%, 2.5 vol%, 5 vol%, 6 vol% and 8 vol%. ⋯ Full validation was performed to assure the suitability of the method for preparing gas mixtures to calibrate anesthetic gas monitors. Linearity, limit of detection (LOD), limit of quantification (LOQ), precision, method robustness and uncertainty of measurement results were evaluated in the validation study. The results indicated that the method is valid for the purpose of analysis.
-
J Clin Monit Comput · Oct 2021
Randomized Controlled TrialEvaluation of the Integrated Pulmonary Index® during non-anesthesiologist sedation for percutaneous endoscopic gastrostomy.
Standard monitoring of heart rate, blood pressure and arterial oxygen saturation during endoscopy is recommended by current guidelines on procedural sedation. A number of studies indicated a reduction of hypoxic (art. oxygenation < 90% for > 15 s) and severe hypoxic events (art. oxygenation < 85%) by additional use of capnography. Therefore, U. ⋯ Sensitivity is good for most parameters, but specificity is poor. In conclusion, IPI can be a useful metric to assess respiratory status during propofol-sedation in PEG-placement. However, IPI was not superior to PetCO2 and apnea > 10 s.
-
J Clin Monit Comput · Oct 2021
Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis.
Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform displayed on any patient monitor. We evaluated the PPV and CO measurement performance of PWAsnap in adults having major abdominal surgery. ⋯ In adults having major abdominal surgery, PPVPWAsnap moderately agrees with PPVProAQT. The absolute and trending agreement between COPWAsnap with COProAQT is poor. Technical improvements are needed before PWAsnap can be recommended for hemodynamic monitoring.
-
J Clin Monit Comput · Oct 2021
Trans-ocular brain impedance index for assessment of cerebral autoregulation in a porcine model of cerebral hemodynamic perturbation.
Cerebrovascular autoregulation (CA) is often impaired following traumatic brain injury. Established technologies and metrics used to assess CA are invasive and conducive for measurement, but not for continuous monitoring. We developed a trans-ocular brain impedance (TOBI) method that may provide non-invasive and continuous indices to assess CA. ⋯ Receiver operator curve test showed high predictive performance of DZx when compared to PRx with area under the curve above 0.86, with high sensitivity and specificity. Impedance indices appear to track changes in PRx and hemodynamics that affect cerebral autoregulation. TOBI may be a suitable less invasive surrogate to PRx and capable of tracking cerebral autoregulation.