The Journal of thoracic and cardiovascular surgery
-
J. Thorac. Cardiovasc. Surg. · Jun 2016
Comparative StudyA pulsatile hemodynamic evaluation of the commercially available bifurcated Y-graft Fontan modification and comparison with the lateral tunnel and extracardiac conduits.
Fontan completion, resulting in a total cavopulmonary connection, is accomplished using a lateral tunnel, extracardiac conduit, or bifurcated Y-graft. The use of Y-grafts is hypothesized to provide symmetric hepatic blood flow distribution to the lungs, a factor related to pulmonary arteriovenous malformations. The present study evaluates the hemodynamic performance of the largest commercially available Y-graft cohort to date, highlights 6 representative cases, and compares commercially available Y-graft performance with lateral tunnel/extracardiac conduit connections. ⋯ Commercially available Y-grafts do not inherently provide more balanced hepatic flow distribution than lateral tunnel/extracardiac conduit connections, which are more energetically favorable and less sensitive to pulmonary artery stenosis. Graft type should be considered on an individual basis because hemodynamic performance is based on a combination of factors, including pulmonary flow distribution, pulmonary artery stenosis, and superior vena cava positioning.