Recent advances in technology and the refinement of neurophysiological methodologies are significantly changing intraoperative neurophysiological monitoring (IOM) of the spinal cord. This review will summarize the latest achievements in the monitoring of the spinal cord during spine and spinal cord surgeries. This overview is based on an extensive review of the literature and the authors' personal experience. ⋯ Finally, while MEPs are now considered the gold standard for monitoring the motor pathways, SEPs continue to retain value as they provide specificity for assessing the integrity of the dorsal column. However, we believe SEPs should not be used exclusively--or as an alternative to motor evoked potentials--during spine surgery, but rather as a complementary method in combination with MEPs. For intramedullary spinal tumor resection, SEPs should not be used exclusively without MEPs.