For percutaneously tracheostomized patients with prolonged weaning and persisting respiratory failure, the adequate time point for safe decannulation and switch to noninvasive ventilation is an important clinical issue. ⋯ In percutaneously tracheostomized patients with prolonged weaning, the use of a TR seems to facilitate and improve the weaning process considerably. The duration of spontaneous breathing prior to decannulation, age and oxygenation describe the risk for recannulation in these patients.
-
An alveolar-pleural fistula is a communication between the pulmonary parenchyma distal to a segmental bronchus and the pleural space. A postoperative pulmonary expiratory air leak after an anatomic pulmonary resection is usually managed conservatively. ⋯ Our case also illustrates that, even after lobectomy, lobar exclusion with valves allows air leak resolution without atelectasis and with moderate functional alteration. We discuss the anatomic and physiologic changes induced by valves placed for air leak closure.
-
Serum levels of pneumocyte biomarkers KL-6 and surfactant protein D (SP-D) are useful diagnostic markers for interstitial lung diseases. However, associations of serum KL-6 and SP-D with radiologic findings in nonspecific interstitial pneumonia (NSIP) remain unclear. ⋯ The results indicate that serum levels of KL-6 in NSIP reflect the overall extent of interstitial lesions, which include both inflammatory and fibrotic lesions, while the levels of SP-D mainly reflect the extent of inflammatory lesions.
-
Comparative Study
What does built-in software of home ventilators tell us? An observational study of 150 patients on home ventilation.
Recent home ventilators are equipped with built-in software which provides data such as compliance, estimations of leaks, tidal volume, minute ventilation, respiratory rate, apnea and apnea-hypopnea indexes, and percentage of inspirations triggered by the patient (or ventilator). However, for many of these variables, there is neither consensus nor documentation as to what is to be expected in a population of stable patients under noninvasive ventilation (NIV). ⋯ Built-in software of home ventilators provides the clinician with new parameters, some of which are a useful adjunct to recommended tools for monitoring NIV and may contribute to a better understanding of residual hypoventilation and/or desaturations. However, an independent validation of the accuracy of this information is mandatory.