A&A practice
-
Spinal cord stimulation (SCS) is a minimally invasive procedure used for a broad spectrum of chronic pain conditions. Unfortunately, complications can occur that may lead to device explantation. ⋯ To our knowledge, salvage therapy with high-frequency SCS for LoE with burst SCS has not been previously described. We present a case of salvage therapy utilizing 10 kHz SCS for LoE with a passive recharge burst SCS.
-
We report a case of severe shivering resulting in rhabdomyolysis while on venoarterial extracorporeal membrane oxygenation (ECMO) that resolved after hyperthermia was induced using the ECMO circuit. The patient developed shivering approximately 24 hours after venoarterial ECMO cannulation for refractory ventricular tachycardia. ⋯ Suspecting sepsis as the etiology of shivering, the ECMO circuit temperature was increased to 38 °C, and the shivering was resolved. This case demonstrates therapeutic hyperthermia to treat infection-induced severe shivering and rhabdomyolysis while on ECMO.
-
Iatrogenic aortic injury is a rare but potentially lethal complication of cardiac surgery. While sometimes resulting in aortic dissection or intramural hematoma, injury more frequently results in subadventitial hematoma, a more benign pathology. ⋯ Epiaortic ultrasound was subsequently performed, which definitively demonstrated the absence of a dissection flap or extraluminal flow. Per our review, this is the first report documenting the successful use of epiaortic imaging to identify subadventitial hematoma in the setting of inconclusive TEE findings.
-
The inadvertent crossover between O2 and N2O pipelines has become extremely rare in practice. We describe a case where it was possible to ventilate with 100% N2O instead of the intended 100% O2 on a modern anesthesia delivery system (Dräger Apollo; Drägerwerk AG & Co KgaA, Lübeck, Germany). This was the result of the incorrect assembly of diameter index safety system (DISS) components during preventative maintenance that defeated the DISS failsafe system. To make incorrect assembly easier to avoid, DISS component labeling could be more prominent and color-coded, or the internal construction of the gas manifold could incorporate DISS.
-
We present the case of a 7-month-old infant undergoing thoracotomy and left lower lobe lobectomy who experienced a significant complication related to lung isolation with a bronchial blocker. Despite good isolation and seemingly appropriate positioning, the bronchial blocker became entrapped within the staple line at the bronchial stump. Fortunately, the surgeon was able to free the blocker. Going forward, we recommend clinicians be vigilant in positioning the blocker just distal to the carina in all cases and, further, consider retracting the blocker into the trachea before surgical intervention on the airway to avoid inadvertent entrapment of the device.