A&A practice
-
Case Reports
Tricuspid Valve Avulsion After Blunt Chest Wall Trauma: A Case Report for Urgent Valve Replacement.
Tricuspid valve (TV) avulsion is rare and ordinarily does not require emergent intervention. We present the case of a polytrauma patient with traumatic TV avulsion who ultimately required urgent TV replacement in the setting of hemodynamic instability. Urgent TV replacement may be warranted after careful consideration of patient risk factors and clinical context.
-
We present a case of a pediatric patient who developed recurarization after a cardiac catheterization procedure. Intraoperative neuromuscular blockade was achieved with 2 doses of rocuronium, and the blockade was reversed with a bolus dose of sugammadex at the end of the procedure. While recovering in the pediatric cardiac intensive care unit, the patient developed respiratory failure and a decline in the train-of-four response. The patient fully recovered after receiving a second dose of sugammadex.
-
Case Reports
Fetus-in-Fetu Airway Teratoma Management of a Newborn in a Low-Resource Country: A Case Report.
A term baby was delivered by cesarean and found to have an unexpected large teratoma attached to its mouth. Surgical excision was planned within 24 hours. Anesthesia concern of airway control required multidisciplinary team consultation, airway and patient preparation, and anticipation for failure. Challenging airway cases in low-resource countries can be successfully managed with deliberate attention to detail, preparation, and experience.
-
We report a case of subcutaneous implantable cardioverter-defibrillator implantation in a morbidly obese pediatric patient with hypertrophic cardiomyopathy for the primary prevention of sudden cardiac death. During routine defibrillator threshold testing of the newly placed subcutaneous implantable cardioverter defibrillator, normal sinus rhythm could not be restored despite repeated attempts at defibrillation using the subcutaneous implantable cardioverter defibrillator and transcutaneous pads. Here, we describe the successful intraoperative resuscitation and management after failure to restore normal sinus rhythm using the newly placed subcutaneous implantable cardioverter defibrillator and repeated transcutaneous defibrillation attempts.
-
Case Reports
Large Iatrogenic Tracheal Injury From Attempted Endotracheal Cuff Leak Remedy: A Case Report.
Continuous insufflation of oxygen into the pilot balloon of an endotracheal tube has been documented as a viable method to fix an incompetent endotracheal tube cuff. We present a case of a large iatrogenic tracheal injury resulting from an improvised cuff leak management device. Valuable lessons are discussed to prevent similar incidents.