Circulation
-
Aortic dissection still has a poor prognosis despite progress in therapy. Therefore, this prospective follow-up study was designed to determine whether the degree of communication between true and false lumen in relation to the type of dissection, analyzed by transesophageal echocardiography, influences the risk after initiation of medical or surgical therapy. ⋯ Preoperative mortality appears to be reduced by transesophageal echocardiography, allowing rapid initiation of treatment. Intraoperative and postoperative mortality in aortic dissection remains high. Risk factors are fluid extravasation and an open false lumen with high communication. Thrombus formation in the false lumen can be regarded as a good prognostic sign. Surgery appears to be only a first step in the treatment of aortic dissection. Second surgery or closure of entry sites based on intraoperative echocardiography may be considered to induce thrombus formation and reduce aortic wall stress.