Journal of neurosurgery. Spine
-
The lateral retroperitoneal transpsoas approach is being increasingly employed to treat various spinal disorders. The minimally invasive blunt retroperitoneal and transpsoas dissection poses a risk of injury to major nervous structures. The addition of electrophysiological monitoring potentially decreases the risk of injury to the lumbar plexus. With respect to the use of the direct transpsoas approach, however, there is sparse knowledge regarding the relationship between the retroperitoneum/psoas muscle and the lumbar plexus at each lumbar segment. The authors undertook this anatomical cadaveric dissection study to define the anatomical safe zones relative to the disc spaces for prevention of nerve injuries during the lateral retroperitoneal transpsoas approach. ⋯ With respect to prevention of direct nerve injury, the safe anatomical zones at the disc spaces from L1-2 to L3-4 are at the middle posterior quarter of the VB (midpoint of Zone III) and the safe anatomical zone at the L4-5 disc space is at the midpoint of the VB (Zone II-Zone III demarcation). There is risk of direct injury to the genitofemoral nerve in Zone II at the L2-3 space and in Zone I at the lower lumbar levels L3-4 and L4-5. There is also a potential risk of injury to the ilioinguinal, iliohypogastric, and lateral femoral cutaneous nerves in the retroperitoneal space where they travel obliquely, inferiorly, and anteriorly to the reach the iliac crest and the abdominal wall.
-
Comparative Study Clinical Trial
Healos graft carrier with bone marrow aspirate instead of allograft as adjunct to local autograft for posterolateral fusion in degenerative lumbar scoliosis: a minimum 2-year follow-up study.
The objective of this study was to examine the efficacy and safety of Healos graft carrier with bone marrow aspirate and local autograft compared with the results of allograft in patients with lumbar degenerative scoliosis undergoing posterolateral fusion. ⋯ The combination of Healos hydroxyapatite sponge and bone marrow aspirate plus local allograft had significantly slower fusion rates but equal clinical outcomes compared with cancellous allograft plus local autograft when used for posterolateral fusion in patients with degenerative lumbar scoliosis.
-
Clinical Trial
Efficacy and limitations of intraoperative spinal cord monitoring using nasopharyngeal tube electrodes.
Motor evoked potentials are widely used for intraoperative spinal cord monitoring. However, there are problems with anesthetic constraints and high trial-by-trial variability of compound muscle action potential amplitude in muscle motor evoked potential monitoring. It is difficult to determine when to warn the surgeon of an occurrence of spinal cord risk. A method of estimation for motor function in the spinal cord has not been established. To monitor spinal cord function with reliable evoked potentials, including the upper cervical spinal cord and the ventral spinal cord, the authors developed a nasopharyngeal tube electrode that can be placed in front of the upper and ventral cervical spinal cord. The purpose of this study was to investigate the origins and pathways of descending or ascending spinal cord evoked potentials (SCEPs) elicited with this electrode, and the usefulness and limitations of this method. ⋯ Combined recording of both SCEPs estimated the ventral and dorsal white matter function in the spinal cord. Measuring the SCEPs with the nasopharyngeal electrode can be another useful approach for upper cervical and thoracic spinal cord monitoring. Ventral SCEP was more reliable for monitoring postoperative spinal cord function than dorsal SCEP. Ventral SCEP does not estimate the gray matter and spinal root functions in the lower cervical spinal cord.
-
Clinical Trial
Surgical site infection in spinal surgery: detection and management based on serial C-reactive protein measurements.
C-reactive protein (CRP) is a well-known sensitive laboratory parameter that shows an increase within 6 hours after the onset of bacterial infection. In relation to surgery, a normal CRP response is a rapid increase followed by a gradual reduction, eventually returning to the normal range. The goal of this study was to determine the diagnostic significance of CRP as a detector for early onset surgical site infection in spinal surgery and to discuss effective medical treatment through clinical interpretation and application of the measured CRP values. ⋯ The above results demonstrate that CRP screening is a simple and reliable test for the detection of early infectious complications after spinal surgery. Close observation and appropriate medical management should be performed in a timely fashion when abnormal CRP responses are observed at 5 or 7 days after surgery.
-
The overall incidence of complications or adverse events in spinal surgery is unknown. Both prospective and retrospective analyses have been performed, but the results have not been critically assessed. Procedures for different regions of the spine (cervical and thoracolumbar) and the incidence of complications for each have been reported but not compared. Authors of previous reports have concentrated on complications in terms of their incidence relevant to healthcare providers: medical versus surgical etiology and the relevance of perioperative complications to perioperative events. Few authors have assessed complication incidence from the patient's perspective. In this report the authors summarize the spine surgery complications literature and address the effect of study design on reported complication incidence. ⋯ Retrospective reviews significantly underestimate the overall incidence of complications in spine surgery. This analysis is the first to critically assess differing complication incidences reported in prospective and retrospective cervical and thoracolumbar spine surgery studies.