Journal of neurosurgery. Spine
-
Randomized Controlled Trial
Neuromonitoring with pulse-train stimulation for implantation of thoracic pedicle screws: a blinded and randomized clinical study. Part 1. Methods and alarm criteria.
Reports of the accuracy of existing neuromonitoring methods for detecting or preventing medial malpositioning of thoracic pedicle screws have varied widely in their claimed effectiveness. The object of this study was to develop, test, and validate a novel neuromonitoring method for preventing medial malpositioning of pedicle screws in the thoracic spine during surgery. ⋯ This novel neuromonitoring approach accurately predicts medially malpositioned thoracic screws. The approach could be readily implemented within any surgical program that is already using contemporary neuromonitoring methods that include transcranial stimulation for monitoring motor evoked potentials.
-
Multicenter Study
Predictors of unplanned readmission in patients undergoing lumbar decompression: multi-institutional analysis of 7016 patients.
Unplanned hospital readmission represents a large financial burden on the Centers for Medicare and Medicaid Services, commercial insurance payers, hospitals, and individual patients, and is a principal target for cost reduction. A large-scale, multi-institutional study that evaluates risk factors for readmission has not been previously performed in patients undergoing lumbar decompression procedures. The goal of this multicenter retrospective study was to find preoperative, intraoperative, and postoperative predictive factors that result in unplanned readmission (UR) after lumbar decompression surgery. ⋯ There were several risk factors for UR after lumbar spine decompression surgery. Identification of high-risk patients and appropriate allocation of resources to reduce postoperative incidence may reduce the readmission rate.
-
Many studies attest to the excellent results achieved using anterior lumbar interbody fusion (ALIF) for degenerative spondylolisthesis. The purpose of this report is to document a rare instance of L-4 vertebral body fracture following use of a stand-alone interbody fusion device for L3-4 ALIF. The patient, a 55-year-old man, had suffered intractable pain of the back, right buttock, and left leg for several weeks. ⋯ Again, degenerative spondylolisthesis improved postsurgically and symptoms eased, with eventual healing of the vertebral body fracture. This report documents a rare instance of L-4 vertebral body fracture following use of a stand-alone device for ALIF at L3-4, likely as a consequence of angular instability in degenerative spondylolisthesis. Under such conditions, additional pedicle screw fixation is advised.
-
Patients with recurrent sciatica due to repeated reherniation of the intervertebral disc carry a poor prognosis for recovery and create a large burden on society. There is no consensus about the best treatment for this patient group. The goal of this study was to evaluate the 12-month results of the placement of stand-alone Trabecular Metal cages in these patients. ⋯ Although only 46% of patients reported a good recovery with significant reductions in back and leg pain, 85% of patients reported at least some benefit from the operation, and a marked improvement in working status at follow-up was noted. In view of previously published poor results of instrumented lumbar fusion for patients with failed back surgery syndrome, the present data indicate that Trabecular Metal interbody fusion cages can be used in a stand-alone fashion and should not always need supplemental posterior fixation in patients with recurrent disc herniation without spinal instability, although a long-term follow-up study is warranted.