Increasing data suggesting that microorganisms in the biofilm form are among the leading agents of persistent infections of chronic wounds require the development of new approaches to treatment. The aim of this article was to compare the efficacy of three commonly used antiseptics using a biofilm-oriented approach. Biofilm-oriented antiseptics test (BOAT), the innovative method, allows to estimate, in a quick and reliable manner, the in vitro activity of working solutions of antiseptics in real contact times against bacteria in the biofilm form and to use the results in the selection of an appropriate antiseptic to treat local infections in the clinical practice.
-
The aim of this study was to determine the prevalence, severity, location, aetiology, treatment and healing of medical device-related pressure ulcers (PUs) in intensive care patients for up to 7 days. A prospective repeated measures study design was used. Patients in six intensive care units of two major medical centres, one each in Australia and the USA, were screened 1 day per month for 6 months. ⋯ In conclusion, device-related ulcer prevalence was 3·1%, similar to that reported in the limited literature available, indicating an ongoing problem. Systematic assessment and repositioning of devices are the mainstays of care. We recommend continued prevalence determination and that nurses remain vigilant to prevent device-related ulcers, especially in patients with NG and ET tubes.
-
This study compared moisture vapour transmission rate (MVTR) and wear time or fluid-handling capacities of six adhesive foam dressings to a reformulated control dressing. Standardised in vitro MVTR methodology and a previously published in vivo artificial wound model (AWM) were used. Mean inverted MVTR for the reformulated dressing was 12 750 g/m(2) /24 hours and was significantly higher than four of the six comparator dressings (P < 0·0001), which ranged from 830 to 11 360 g/m(2) /24 hours. ⋯ Interestingly, inverted MVTR did not correspond well to the AWM. These results suggest that marked differences exist between the dressings in terms of both MVTR and wear time or fluid-handling capacity. Furthermore, high inverted MVTR does not necessarily predict longer wear time or fluid-handling capacities of absorbent dressings.
-
Ionic silver has a long history as an antimicrobial in human health care. This article is a review of the published literature on how ionic silver may enter the body from exposure to silver-containing wound care products and its eventual metabolic fates, in an assessment of the safety during normal use of these products in wound care. Following the application to breached skin, there appears to be little evidence of localised or systemic toxicity, and this is borne out by the continuous use of silver sulfadiazine formulations for more than 50 years. Consequently, following normal use, the risk of silver ion toxicity locally and systemically is considered to be low or negligible.
-
Case Reports
Perioperative use of bispectral (BIS) monitor for a pressure ulcer patient with locked-in syndrome (LIS).
The bispectral (BIS) monitor uses brain electroencephalographic data to measure the depth of sedation and pharmacological response during anaesthetic procedures. In this case, the BIS monitor was used for another purpose, to demonstrate postoperatively to the nursing staff that a patient with history of locked-in syndrome (LIS), who underwent pressure ulcer debridement, had periods of wakefulness and apparent sensation, even with his eyes closed. ⋯ This use of the BIS has shown that as a general rule, the staff should treat the patient as though he might be awake and sensate even if he does not open his eyes or move his limbs. The goal of this study was to continuously monitor pain level and communicate these findings to the entire wound team, i.e. anaesthesiologists, surgeons and nurses.