The American journal of cardiology
-
Randomized Controlled Trial
Effect of Ambrisentan on Exercise Capacity in Adult Patients After the Fontan Procedure.
The Fontan operation is a common end point for children born with a single functional ventricle. Fontan patients typically experience physiological deterioration leading to transplant or death in their third or fourth decades of life. This deterioration is partially attributable to progressive increases in pulmonary vascular resistance (PVR) and as such endothelin receptor antagonists, which are known to decrease pulmonary vascular resistance, have been proposed as potentially beneficial in this population. ⋯ Ambrisentan therapy resulted in a decrease in (-1.4 g/dl, p <0.001) with no change in liver or renal function. Therapy was generally well tolerated, with no greater rate of side effects than placebo. In conclusion, ambrisentan is well tolerated and improves exercise capacity in adult Fontan patients.
-
Randomized Controlled Trial Multicenter Study
Impact of Anesthesia Type on Outcomes of Transcatheter Aortic Valve Implantation (from the Multicenter ADVANCE Study).
Transcatheter aortic valve implantation (TAVI) has become the standard of care for many patients with symptomatic severe aortic stenosis who are at increased risk of morbidity and mortality during surgical aortic valve replacement. However, there is still no general consensus regarding the use of general anesthesia (GA) versus local anesthesia with sedation (non-GA) during the TAVI procedure. Using propensity score-matching analysis, we analyzed the characteristics and outcomes of patients who underwent TAVI with either GA (n = 245) or non-GA (n = 245) in the fully monitored, international, CoreValve ADVANCE Study. ⋯ Both GA and non-GA are widely used in real-world TAVI practice, and the decision appears to be guided by only a few patient-related factors and dominated by local and national practice. The outcomes of both anesthesia modes are equally good. When conversion from non-GA did occur, the complication requiring GA affected outcomes.
-
Randomized Controlled Trial Multicenter Study
Three-Year Outcomes of Transcatheter Aortic Valve Implantation in Patients With Varying Levels of Surgical Risk (from the CoreValve ADVANCE Study).
This study compared 3-year clinical outcomes of patients who underwent transcatheter aortic valve implantation with the Society of Thoracic Surgeons (STS) score ≤7% to those of patients with a score >7%. Data were drawn from the ADVANCE study, a multinational post-market clinical trial that enrolled real-world patients with severe aortic stenosis treated with the CoreValve bioprosthesis. Events were independently adjudicated using Valve Academic Research Consortium-1 definitions. ⋯ Conversely, the severity of AR at discharge did not affect 3-year mortality in patients with STS >7% (42.9% vs 44.6%, moderate/severe vs mild/less; hazard ratio 1.04; 95% confidence interval, 0.62 to 1.75; p = 0.861; p for interaction = 0.047). In conclusion, patients with STS ≤7% had lower rates of all-cause and cardiovascular mortality at 3 years after transcatheter aortic valve implantation. Complication rates were low and stable in both groups, demonstrating the safety of this procedure for patients at various levels of surgical risk.
-
Randomized Controlled Trial
Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study).
Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and programming strategies have significantly reduced the incidence of inappropriate shocks, but there are still gains to be made with respect to reducing appropriate but unnecessary antitachycardia pacing (ATP) and shocks. We examined whether programming a number of intervals to detect (NID) of 60/80 for ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) detection was safe and the impact of this strategy on (1) adverse events related to ICD shocks and syncopal events; (2) ATPs/shocks; and (3) patient-reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. ⋯ Because of the new programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life.
-
Randomized Controlled Trial
Effects of Single and Multiple Energy Shots on Blood Pressure and Electrocardiographic Parameters.
We assessed the effects of single and multiple caffeinated energy shots on hemodynamic and electrocardiographic (ECG) parameters. This was a randomized, double-blinded, placebo-controlled, crossover study in otherwise healthy volunteers (n = 26) where a caffeinated energy shot or matching placebo was ingested. The study drink was consumed twice daily for 7 days during each phase, with a 7-day washout period in between. ⋯ In conclusion, a single shot of a caffeinated energy drink significantly raised systolic and diastolic BPs. However, these elevations were not sustained with chronic consumption. ECG parameters were not altered.