Early referral for ablation of scar-related ventricular tachycardia is associated with improved acute and long-term outcomes: results from the Heart Center of Leipzig ventricular tachycardia registry.
The effects of time to referral for catheter ablation (CA) of scar-related ventricular tachycardia (VT) on acute success, VT recurrence, and cardiac mortality are unclear. ⋯ CA of scar-related VT performed within 30 days after the first documented VT was associated with improved acute and long-term success. VT recurrence, but not the early referral for CA, was associated with cardiovascular mortality.
-
Circ Arrhythm Electrophysiol · Dec 2014
Randomized Controlled Trial Multicenter StudyInteraction between digoxin and dronedarone in the PALLAS trial.
Elevated serum digoxin concentration can cause toxicity, including death. Dronedarone increases digoxin concentration by P-glycoprotein interaction. In Permanent Atrial Fibrillation Outcome Study Using Dronedarone On Top Of Standard Therapy Trial (PALLAS), dronedarone was associated with both increased cardiovascular death and heart failure in patients with permanent atrial fibrillation. The present analysis examines whether the dronedarone-digoxin interaction might explain these adverse outcomes. ⋯ http://www.clinicaltrials.gov. Unique identifier: NCT01151137.
-
Circ Arrhythm Electrophysiol · Dec 2014
Multicenter Study Observational StudyProtein biomarkers identify patients unlikely to benefit from primary prevention implantable cardioverter defibrillators: findings from the Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSE-ICD).
Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality, but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation, and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs. ⋯ clinicaltrials.gov; Unique Identifier: NCT00733590.
-
Circ Arrhythm Electrophysiol · Dec 2014
Multicenter StudyREPLACE DARE (Death After Replacement Evaluation) score: determinants of all-cause mortality after implantable device replacement or upgrade from the REPLACE registry.
Identifying factors predictive of mortality may be important to decrease risk associated with cardiac implantable electrical device (CIED) replacement procedures. This study aimed to determine whether clinical factors and complications independently associate with death and to develop a mortality risk prediction tool after CIED replacement. ⋯ http://www.clinicaltrials.gov. Unique identifier: NCT00395447.