Multicenter Study Comparative Study Observational StudyBalloon Versus Self-Expandable Valve for the Treatment of Bicuspid Aortic Valve Stenosis: Insights From the BEAT International Collaborative Registrys.
Large data comparing the performance of new-generation self-expandable versus balloon-expandable transcatheter heart valves in bicuspid aortic stenosis are lacking. We aim to compare the safety and performance of balloon-expandable and self-expandable transcatheter heart valves in the treatment of bicuspid aortic stenosis. ⋯ Our study confirms the feasibility of both Sapien 3 and Evolut R/PRO implantation in bicuspid aortic valve anatomy; a higher rate of moderate-severe paravalvular aortic regurgitation was observed in the Evolut R/PRO group at 1-year follow-up in the matched cohort, although patients treated with balloon-expandable valve had a higher rate of annular rupture.
-
Circ Cardiovasc Interv · Jun 2020
Multicenter StudyPredictors of Treatment Response Following Ultrasound-Facilitated Catheter-Directed Thrombolysis for Submassive and Massive Pulmonary Embolism: A SEATTLE II Substudy.
Little is known about which factors predict improvement in clinical and imaging parameters among patients undergoing catheter-directed thrombolysis for submassive or massive pulmonary embolism. The identification of such predictors may allow for more appropriate patient selection for ultrasound-facilitated catheter-directed thrombolysis. ⋯ Patients with more life-threatening pulmonary embolism may derive the greatest benefit from ultrasound-assisted, catheter-directed thrombolysis.
-
Circ Cardiovasc Interv · May 2020
Multicenter Study Comparative StudyOutcomes of Cardiac Catheterization in Patients With Atrial Fibrillation on Anticoagulation in Contemporary in Practice: An Analysis of the ORBIT II Registry.
Patients with atrial fibrillation on oral anticoagulation (OAC) undergoing cardiac catheterization face risks for embolic and bleeding events, yet information on strategies to mitigate these risks in contemporary practice is lacking. ⋯ In a real-world registry of patients with atrial fibrillation undergoing cardiac catheterization, most cases are elective, performed by femoral access, with interruption of OAC. Bleeding avoidance strategies such as radial artery access and bivalirudin were used infrequently and use of bridging therapy was uncommon. Nearly 40% of patients did not restart OAC postprocedure, exposing patients to risk for stroke. Further research is necessary to optimize the management of patients with atrial fibrillation undergoing cardiac catheterization.