Clinics in orthopedic surgery
-
Comparative Study
Comparison of results between hook plate fixation and ligament reconstruction for acute unstable acromioclavicular joint dislocation.
In the present study, we aimed to compare clinical and radiographic outcomes between hook plate fixation and coracoclavicular (CC) ligament reconstruction for the treatment of acute unstable acromioclavicular (AC) joint dislocation. ⋯ In cases of acute unstable AC joint dislocation, hook plate fixation and CC ligament reconstruction yield comparable satisfactory clinical outcomes. However, radiographic outcomes based on the maintenance of reduction indicate that hook plate fixation is a better treatment option.
-
The single radius total knee prosthesis was introduced with the advantage of reduced patellar symptoms; however, there is no long-term follow-up study of the same. The purpose of this study was to determine the survival rate of single radius posterior-stabilized total knee arthroplasty and patellofemoral complication rates in a consecutive series. ⋯ The single radius posterior-stabilized total knee prosthesis demonstrated an excellent minimum 10-year survivorship. The low rates of implant loosening and 7.5% of anterior knee pain as a patellofemoral complication are comparable with those reported for other modern total knee prosthesis.
-
The Targon FN implant was developed in 2007 to treat intracapsular neck of femur fractures. Early results from the design centre have shown good results in terms of fracture complications. We wished to see if these results can be reproduced in an independent institution. ⋯ Our study shows similar results with those of the design centre and which are superior to those currently found in the literature for the more traditional fixation methods. It also shows that the promising results with this new implant as seen from the design institutions can be reproduced by all cadres of surgeons in non-specialist practice.
-
As surgical complications tend to occur more frequently in the beginning stages of a surgeon's career, knowledge of perioperative complications is important to perform a safe procedure, especially if the surgeon is a novice. We sought to identify and describe perioperative complications and their management in connection with minimally invasive transforaminal lumbar interbody fusion (TLIF). ⋯ We found perioperative complications occurred more often in the early period of a surgeon's experience with minimally invasive TLIF. Implant-related complications were common and successfully managed by additional surgeries in this series. We suggest greater caution should be exercised to avoid the potential complications, especially when surgeon is a novice to this procedure.
-
Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and infiltration of the metal particles in this catastrophic condition. ⋯ The survival rate of revision total hip arthroplasty in patients with metallosis following a catastrophic failure of a PE liner was low.