Injury
-
Multicenter Study
Current concepts in the treatment of Anderson Type II odontoid fractures in the elderly in Germany, Austria and Switzerland.
Although currently there are many different recommendations and strategies in the therapy of odontoid fractures in the elderly, there are still no generally accepted guidelines for a structured and standardised treatment. Moreover, the current opinion of spine surgeons regarding the optimal treatment of odontoid fractures Type II of the elderly is unknown. In order to have an objective insight into the diverging strategies for the management of Anderson Type II odontoid fractures and form a basis for future comparisons, this study investigated the current concepts and preferences of orthopaedic, neuro- and trauma surgeons. ⋯ The most favoured technique in revision surgery of nonunions was the open posterior Magerl transarticular fusion technique, chosen by 38.6% of respondents. 18.2% preferred the posterior Harms C1/C2 fusion technique, 11.4% the percutaneous posterior Magerl technique and the anterior odontoid screw fixation in each case. This study discovered major variations in the treatment of Anderson Type II odontoid fractures in the elderly in terms of indication for conservative and operative treatment between several treatment centres in 3 European countries. Difficulty and complexity in formulating general guidelines based on multicenter studies is conceivable.
-
Comparative Study
Comparison of stability of two kinds of sacro-iliac screws in the fixation of bilateral sacral fractures in a finite element model.
To compare the stability of lengthened sacro-iliac screw and sacro-iliac screw for the treatment of bilateral vertical sacral fractures to provide reference for clinical application. ⋯ S1 and S2 lengthened sacro-iliac screws should be used for the fixation in bilateral sacral fractures of Tile C pelvic ring injury as far as possible and the most stable fixation is the combination of the lengthened sacro-iliac screws of S1 and S2 segments. Even if lengthened sacro-iliac screws cannot be used due to limited conditions, two bidirectional sacro-iliac screw fixation in S1 and S2 segments, respectively, is recommended. No matter which kind of sacro-iliac screw is applied, the fixation combination of S1 and S2 segments is strongly recommended to maximise the stability of the pelvic posterior ring.
-
To compare the cervical status after neck sprains in frontal and rear-end car impacts with respect to earlier proposed neck-sprain injury mechanisms, rotated head at impact, and the seat-belt geometry. ⋯ The cervical status after neck sprains in frontal and rear-end car impacts is very similar, and the cervical range of movement in different directions and increased pain during cervical motions do not reveal any specific isolated injury mechanisms. Combined injury mechanisms should be considered, and further studies are recommended to investigate asymmetric loading during impact.
-
Vertebral fractures are a common consequence of osteoporosis in older persons. With the ageing of the population, numbers are expected to rise. ⋯ Vertebral fracture related ED visits and hospitalizations are increasing rapidly in the older Dutch population, especially in the oldest-old. Most vertebral fractures were associated with falls. These findings indicate that a pro-active approach in the diagnosis and treatment of osteoporosis and in the prevention of falls in both men and women is warranted.
-
Comparative Study
Biomechanical comparison of different acetabular plate systems and constructs--the role of an infra-acetabular screw placement and use of locking plates.
The aim of this study was the direct comparison of the static fixation strength of two common plate systems: MPS (Matta Pelvic System) and LPPS (Low Profile Plate System). Furthermore the role of a modified screw placement with addressing the infra-acetabular corridor and the use of locking screws were evaluated. ⋯ The LPPS-plate performed superior fixation strength for anterior column fractures compared to the MPS-plate. The locking plate modality did not reduce the maximum fracture displacement, whereas the additional infra-acetabular screw placement actually doubles the fracture fixation strength independent of the used plate system.