Injury
-
The outcome of pathological fracture due to large aggressive benign stage 3 Dormans and Flynn lesions [6] is often unsatisfactory and the rate of recurrence is high. No single technique has been considered safe and successful. Many Authors suggested curettage and bone grafting as the unique effective treatment in cases of large defect but, because of the invasive and complex nature of the operation (it needs a double-step procedure), it is not preferred. The purpose of this study is to examine the effectiveness of a minimally invasive treatment in one step through ESIN, curettage and packing with self-setting calcium phosphate cement. ⋯ The proposed three-in-one procedure has shown to be efficient, cost-effective, associated to high rates of definitive bone healing and low incidence of adverse effects.
-
Heterotopic Ossification (HO) is a well-recognized complication following acetabular fracture fixation and its presence is prognostic for suboptimal clinical outcome. There are many controversies pertaining to its aetiology, including surgical approach, associated injuries and the use of HO prophylaxis. Long term data from high volume centres is necessary to address these issues. ⋯ The risk factors for developing HO following acetabular fracture fixation are multifactorial and include admission to ICU, associated chest injuries, multiple fractures and delay between injury and surgery. Surgical approach, ipsilateral fractures and tibia and patellar fractures may also play a role. Age over thirty years was the only prognostic factor for developing severe HO.
-
This review will define the role of collagen and within-bone heterogeneity and elaborate the importance of trabecular and cortical architecture with regard to their effect on the mechanical strength of bone. For each of these factors, the changes seen with osteoporosis and ageing will be described and how they can compromise strength and eventually lead to bone fragility.
-
Fixation techniques of periprosthetic fractures are far from ideal although the number of this entity is rising. The presence of an intramedullary implant generates its own fracture characteristics since stiffness is altered along the bone shaft and certain implant combinations affect load resistance of the bone. Influencing factors are cement fixation of the implant, intramedullary locking and extramedullary or intramedullary localization of the implant and the cortical thickness of the surrounding bone. ⋯ Stability of the screw fixation itself can be enhanced by embracement configuration around the intramedullary implant. Poor bone stock quality, often being present in metaphyseal areas limits screw fixation. Cement augmentation is an attractive option in this field to enhance screw purchase.