Injury
-
Calcaneal fractures are uncommon and have a substantial impact on hindfoot function and quality of life. Several surgical treatment options are available; both in surgical approach and type of operation. The aim of this study was to compare functional outcome and quality of life following ORIF and primary arthrodesis. Furthermore, predictors of worse functional outcome were explored. ⋯ Good midterm outcomes following in terms of functional outcome and in quality of life are observed. We observed no statistical significant difference in functional outcome between patients with ORIF and patients with primary arthrodesis. The only predictor of worse functional outcome is a lower socio-economic status.
-
The diagnosis and treatment of ankle fractures has evolved considerably over the past two decades. Recent topics of interest have included indications for operative treatment of isolated lateral malleolus fractures, need for fixation of the posterior malleolus, utilization of the posterolateral approach, treatment of the syndesmosis, and the potential role of fibular nailing. In this update, we concisely review these topics and what to expect in the future literature.
-
Observational Study
Incidence and risk factors of acute kidney injury in the Japanese trauma population: A prospective cohort study.
Previous studies have reported the prevalence and risk factors of acute kidney injury (AKI) in relatively young trauma patients. The aims of this study were to identify the prevalence and risk factors of AKI among older Japanese trauma patients. ⋯ Approximately 20% of trauma patients developed AKI, and the elderly were more likely to develop AKI. Older age, male, greater units of red blood cell transfusions, and underlying CKD were associated with incidence of AKI.
-
Randomized Controlled Trial Comparative Study
Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures.
Unstable intra articular fractures of distal radius are frequently being managed with open reduction and internal fixation. Volar locking plate based on polyetheretherketon (PEEK) polymer has developed lately as an alternative to conventional metallic devices. The advantage of this kind of plates include the lack of metal allergies, radiolucency, low artefacts on MRI or imaging scans and the high resistance associated to loading forces. The aim of this study was to evaluate the clinical and radiological results using a new Carbon-PEEK volar locking plate compared with titanium volar locking plates for the treatment of distal radius fractures. ⋯ Volar locking plates represent the most common procedure for the treatment of displaced distal radius fractures. In our series Carbon-peek volar locking plates seems to be analogue to titanium volar locking plates in terms of radiographic parameters and functional outcome.
-
Comparative Study
Blood loss in trochanteric fractures: multivariate analysis comparing dynamic hip screw and Gamma nail.
Anaemia in patients with trochanteric fracture is associated with increased morbidity and mortality and it is an independent risk factor for functional mobility of patients. Several authors have reported the blood loss following operative treatment comparing different fixation systems but few authors have evaluated many associated variables that could influence the perioperative blood loss. ⋯ According to the perioperative blood loss, DHS should be used in A1 fractures while Gamma nail can be taking in account for the unstable A2 fractures.