Injury
-
Multicenter Study
Proposal for the classification of peri-implant femoral fractures: Retrospective cohort study.
Background Peri-implant fractures occur in association with an implant used to treat a previous injury and that is still attached to the bone. Peri-implant fractures are considered to be relatively "new" fractures and they lack any classification system that is accepted in practice. Generally, the fracture classification systems currently used in our clinical practice were not developed or validated using rigorous scientific evaluation methods. ⋯ The highest proportion of peri-implant femoral fractures corresponded to #31-AN (trochanteric and neck area) and #32-CNP (diaphysis fractures distant from the implant, often distal and spiral). Conclusion The proposed classification for peri-implant femoral fractures appears to be useful and easy to accomplish. Future studies will be necessary to validate it and demonstrate the effectiveness of its application in clinical practice.
-
The purpose of this article was to introduce calcaneal lengthening for partial traumatic loss of the calcaneus. Effectiveness with the use of the technique was also assessed. ⋯ For the treatment of partial traumatic loss of the calcaneus, calcaneal lengthening using an Ilizarov frame is a preferable technique to restore the length of calcaneus and foot function.
-
It is common practice when placing cannulated screws within the femoral head when treating femoral neck fractures to avoid the thread-forms from crossing the fracture line. Despite the widespread use of cannulated screws in internal fixation of femoral neck fractures, there is no study to our knowledge that describes the ideal length of thread-forms. ⋯ In conclusion, we propose an additional lag screw thread form with length 26.0 mm to capture 90% of femoral neck fractures.
-
Prophylactic femoral neck fixation may be performed in the setting of geriatric diaphyseal femur fracture, pathologic or impending atypical femur fractures. Fixation constructs often utilize cephalomedullary implants with one or two proximal interlocking screws into the femoral head/neck. Variations in proximal femoral anatomy and implant design can interfere with the placement of two screws in the femoral head and neck. Our objective was to assess the strength of piriformis entry reconstruction implants with one versus two proximal interlock screws for prophylactic femoral neck fixation. ⋯ Our results demonstrate that piriformis entry reconstruction implants have a significantly lower load to failure compared to an intact femur irrespective of screw construct. Further studies are needed to investigate this potential iatrogenic weakening.
-
The annual incidence of proximal femoral fractures is 100-150/100,000 and continues to increase with an aging population. Cut-out of hip screws after fracture fixation has been quoted as 8% in the literature. The tip-apex distance (TAD) is the strongest predictor for cut-out after operative fracture stabilisation. The aim of this study was to evaluate the novel ADAPT system (Adaptive Positioning Technology, Stryker, USA), a navigation device for intramedullary nailing of trochanteric fractures and its effect on optimising the TAD. This is the first clinical study to evaluate this new technology. ⋯ Working with the novel ADAPT system for positioning the lag screw using the Gamma-3-nail led to a statistically highly significant reduction of the TAD compared to the reference group (p < 0.001). The ADAPT system proved to be a very useful device in achieving higher surgical standards for the treatment of trochanteric fractures with intramedullary nailing. It enables higher accuracy in screw positioning and therefore better placement of the implant.