Anesthesia and analgesia
-
Anesthesia and analgesia · Oct 2000
Randomized Controlled Trial Clinical TrialAggressive warming reduces blood loss during hip arthroplasty.
We evaluated the effects of aggressive warming and maintenance of normothermia on surgical blood loss and allogeneic transfusion requirement. We randomly assigned 150 patients undergoing total hip arthroplasty with spinal anesthesia to aggressive warming (to maintain a tympanic membrane temperature of 36.5 degrees C) or conventional warming (36 degrees C). Autologous and allogeneic blood were given to maintain a priori designated hematocrits. Blood loss was determined by a blinded investigator based on sponge weight and scavenged cells; postoperative loss was determined from drain output. Results were analyzed on an intention-to-treat basis. Average intraoperative core temperatures were warmer in the patients assigned to aggressive warming (36.5 degrees +/- 0.3 degrees vs 36.1 degrees +/- 0.3 degrees C, P< 0.001). Mean arterial pressure was similar in each group preoperatively, but was greater intraoperatively in the conventionally warmed patients: 86+/-12 vs 80+/-9 mm Hg, P<0.001. Intraoperative blood loss was significantly greater in the conventional warming (618 mL; interquartile range, 480-864 mL) than the aggressive warming group (488 mL; interquartile range, 368-721 mL; P: = 0.002), whereas postoperative blood loss did not differ in the two groups. Total blood loss during surgery and over the first two postoperative days was also significantly greater in the conventional warming group (1678 mL; interquartile range, 1366-1965 mL) than in the aggressively warmed group (1,531 mL; interquartile range, 1055-1746 mL, P = 0.031). A total of 40 conventionally warmed patients required 86 units of allogeneic red blood cells, whereas 29 aggressively warmed patients required 62 units (P = 0.051 and 0.061, respectively). We conclude that aggressive intraoperative warming reduces blood loss during hip arthroplasty. ⋯ Aggressive warming better maintained core temperature (36.5 degrees vs 36.1 degrees C) and slightly decreased intraoperative blood pressure. Aggressive warming also decreased blood loss by approximately 200 mL. Aggressive warming may thus, be beneficial in patients undergoing hip arthroplasty.
-
Anesthesia and analgesia · Oct 2000
Randomized Controlled Trial Comparative Study Clinical TrialPercutaneous neuromodulation therapy: does the location of electrical stimulation effect the acute analgesic response?
We studied the effect of the location of electrical stimulation on the acute analgesic response to percutaneous neuromodulation therapy in patients with nonradiating neck pain. Sixty-eight patients received three different nonpharmacologic modalities, namely "needles only" (neck), local (neck) dermatomal stimulation, and remote (lower back) dermatomal stimulation in a random sequence over the course of an 11-wk study period. All treatments were given for 30 min, 3 times per week for 3 wk, with 1 wk "off" between each modality. ⋯ However, the magnitude of the changes in the physical component summary and mental component summary with local dermatomal stimulation was significantly greater (+7.9 and +3.6, respectively) than needle only (+3.4 and +1.7, respectively) or remote dermatomal stimulation (+3.7 and +1.9, respectively). No side effects were reported at the needle insertion sites. We conclude that electrical stimulation at the specific dermatomal levels corresponding to the local pathology produces greater short-term improvements in pain control, physical activity, and quality of sleep in patients with chronic neck pain.
-
Anesthesia and analgesia · Oct 2000
Randomized Controlled Trial Comparative Study Clinical TrialRecovery profiles and costs of anesthesia for outpatient unilateral inguinal herniorrhaphy.
The use of an ilioinguinal-hypogastric nerve block (IHNB) as part of a monitored anesthesia care (MAC) technique has been associated with a rapid recovery profile for outpatients undergoing inguinal herniorrhaphy procedures. This study was designed to compare the cost-effectiveness of an IHNB-MAC technique with standardized general and spinal anesthetics techniques for inguinal herniorrhaphy in the ambulatory setting. We randomly assigned 81 consenting outpatients to receive IHNB-MAC, general anesthesia, or spinal anesthesia. ⋯ Compared with general and spinal anesthesia, patients receiving IHNB-MAC had the shortest time-to-home readiness (133+/-68 min vs. 171+/-40 and 280+/-83 min), lowest pain score at discharge (15+/-14 mm vs. 39+/-28 and 34+/-32 mm), and highest satisfaction at 24-h follow-up (75% vs. 36% and 64%). The total anesthetic costs were also the least in the IHNB-MAC group ($132.73+/-33.80 vs. $172.67+/-29.82 and $164.97+/-31.03). We concluded that IHNB-MAC is the most cost-effective anesthetic technique for outpatients undergoing unilateral inguinal herniorrhaphy with respect to speed of recovery, patient comfort, and associated incremental costs.
-
Anesthesia and analgesia · Oct 2000
Randomized Controlled Trial Comparative Study Clinical TrialRandomized safety studies of intravenous perflubron emulsion. I. Effects on coagulation function in healthy volunteers.
Previous perfluorocarbon (PFC) emulsions have been associated with transient adverse events (i.e., platelet activation, decreased platelet count, febrile responses, changes in hemodynamic function). The Phase I studies described in this report were parallel, randomized, double-blinded, placebo-controlled studies conducted in 48 healthy volunteers (n = 24 per study) with perflubron emulsion (Oxygent; Alliance Pharmaceutical Corp., San Diego, CA). Because of the decreased platelet counts observed with previous PFC emulsions and the intended use of perflubron emulsion in surgical patients, these studies assessed postdosing coagulation responses and hemostasis. ⋯ A 17% reduction in platelet count was observed 3 days after dosing in the 1.8-g PFC/kg group; levels recovered to baseline by Day 7. The intravascular half-life of perflubron for the first 24 h was dose dependent: 9.4+/-2.2 h and 6.1+/-1.9 h in the 1.8- and 1.2-g PFC/kg groups, respectively. Results indicate that this perflubron emulsion did not affect coagulation function in healthy volunteers.
-
Anesthesia and analgesia · Oct 2000
Randomized Controlled Trial Comparative Study Clinical TrialDoes the ProSeal laryngeal mask airway prevent aspiration of regurgitated fluid?
In this randomized, cross-over cadaver study, we determined whether a new airway device, the ProSeal laryngeal mask airway (PLMA; Laryngeal Mask Company, Henley-on-Thames, UK), prevents aspiration of regurgitated fluid. We studied five male and five female cadavers (6-24 h postmortem). The infusion set of a pressure-controlled, continuous flow pump was inserted into the upper esophagus and ligated into place. ⋯ We concluded that in the cadaver model, the correctly placed PLMA allows fluid in the esophagus to bypass the pharynx and mouth when the drainage tube is open. Both the LMA, and PLMA with a closed drainage tube, attenuate liquid flow between the esophagus and pharynx. This may have implications for airway protection in unconscious patients.