Anesthesia and analgesia
-
Anesthesia and analgesia · Dec 2009
Multicenter Study Clinical TrialGlucose as a marker of fluid absorption in bipolar transurethral surgery.
Historically, a reduced serum sodium concentration has been used to diagnose absorption of electrolyte-free irrigating fluid during transurethral resection of the prostate (TURP). In bipolar TURP, the irrigating solution contains electrolytes, thus invalidating the serum sodium method. In this study, we investigated whether glucose can be used to diagnose the absorption of irrigating fluid during TURP procedures. ⋯ In bipolar TURP, the addition of glucose to a concentration of 1% in the electrolyte-containing irrigation fluid can be used as a tracer of absorption that is comparable with measuring serum sodium after monopolar TURP.
-
Anesthesia and analgesia · Dec 2009
Comparative StudyA visual stethoscope to detect the position of the tracheal tube.
Advancing a tracheal tube into the bronchus produces unilateral breath sounds. We created a Visual Stethoscope that allows real-time fast Fourier transformation of the sound signal and 3-dimensional (frequency-amplitude-time) color rendering of the results on a personal computer with simultaneous processing of 2 individual sound signals. The aim of this study was to evaluate whether the Visual Stethoscope can detect bronchial intubation in comparison with auscultation. ⋯ During advancement of the tracheal tube, alterations of the shape of the visualized breath sounds using the Visual Stethoscope appeared before the changes of the breath sounds were detected by auscultation. Bilateral breath sounds disappeared when the tip of the tracheal tube was advanced beyond the carina in both groups.
-
Anesthesia and analgesia · Dec 2009
Comparative StudyA comparison of transmittance and reflectance pulse oximetry during vascular surgery.
New reflectance pulse oximetry probes placed on the forehead may be an improvement over transmittance probes placed on a finger, toe, or earlobe in patients with compromised perfusion. We compared the reliability and accuracy of the 2 types of probes in patients undergoing vascular surgery. ⋯ The new reflectance forehead Spo(2) probe tested has acceptable agreement with the older transmittance probe placed on the earlobe for pulse oximetry within typical ranges of Spo(2) in patients undergoing vascular surgery.
-
Anesthesia and analgesia · Dec 2009
Comparative StudyDefining the reliability of sonoanatomy identification by novices in ultrasound-guided pediatric ilioinguinal and iliohypogastric nerve blockade.
The ilioinguinal (II)/iliohypogastric (IH) nerve block is a safe, frequently used block that has been improved in efficacy and safety by the use of ultrasound guidance. We assessed the frequency with which pediatric anesthesiologists with limited experience with ultrasound-guided regional anesthesia could correctly identify anatomical structures within the inguinal region. Our primary outcome was to compare the frequency of correct identification of the transversus abdominis (TA) muscle with the frequency of correct identification of the II/IH nerves. We used 2 ultrasound machines with different capabilities to assess a potential equipment effect on success of structure identification and time taken for structure identification. ⋯ We have demonstrated that although there is no difference in the overall accuracy of muscle plane versus II/IH nerve identification, the muscle planes are reliably identified after fewer scans of the inguinal region. We suggest that a reliable end point for the inexperienced practitioner of ultrasound-guided II/IH nerve block may be the TA/internal oblique plane where the nerves are reported to be found in 100% of cases.
-
Anesthesia and analgesia · Dec 2009
Comparative StudyThe impact of spontaneous ventilation on distribution of lung aeration in patients with acute respiratory distress syndrome: airway pressure release ventilation versus pressure support ventilation.
In this study, we sought to determine which mode, airway pressure release ventilation (APRV) or pressure support ventilation (PSV), decreases atelectasis more in patients with acute lung injury/acute respiratory distress syndrome (ARDS). ⋯ Spontaneous ventilation during APRV improves lung aeration by decreasing atelectasis. PSV for gas exchange is effective but not sufficient to improve lung aeration. These results indicate that APRV is more efficient than PSV as a mode of primary ventilatory support to decrease atelectasis in patients with ARDS.