Anesthesia and analgesia
-
Anesthesia and analgesia · Oct 2011
Randomized Controlled Trial Comparative StudyDoes the baricity of bupivacaine influence intrathecal spread in the prolonged sitting position before elective cesarean delivery? A prospective randomized controlled study.
Difficulties in inserting an epidural catheter while performing combined spinal-epidural anesthesia for cesarean delivery may lead to undue delays between the spinal injection of the local anesthetic mixture and the adoption of the supine position with lateral tilt. We hypothesized that this delay may affect the intrathecal distribution of local anesthetic of different baricities such that hypobaric local anesthetic would lead to a higher sensory block level. ⋯ We demonstrated that when parturients undergoing cesarean delivery were maintained in the sitting position for 5 minutes after spinal injection of the local anesthetic, hypobaric bupivacaine resulted in sensory block levels that were higher compared with isobaric and hyperbaric bupivacaine, respectively, during the study period.
-
Anesthesia and analgesia · Oct 2011
Randomized Controlled Trial Comparative StudyMaternal cardiac output changes after crystalloid or colloid coload following spinal anesthesia for elective cesarean delivery: a randomized controlled trial.
Minimizing hypotension associated with spinal anesthesia for cesarean delivery by administration of IV fluids and vasopressors reduces fetal and maternal morbidity. Most studies have concentrated on noninvasive systolic blood pressure (SBP) measurements to evaluate the effect of such regimens. We used a suprasternal Doppler flow technique to measure maternal cardiac output (CO) variables in parturients receiving a phenylephrine infusion combined with the rapid administration of crystalloid or colloid solution at the time of initiation of anesthesia (coload). We hypothesized that a colloid coload compared with a crystalloid coload would produce a larger sustained increase in CO and therefore reduce vasopressor requirements. ⋯ We found no difference in CO in women randomized to colloid or crystalloid coload. In addition, there were no differences in vasopressor requirements or hemodynamic stability. We conclude that there is no advantage in using colloid over crystalloid when used in combination with a phenylephrine infusion during spinal anesthesia for elective cesarean delivery.
-
Anesthesia and analgesia · Oct 2011
Randomized Controlled Trial Comparative StudyContinuous femoral versus posterior lumbar plexus nerve blocks for analgesia after hip arthroplasty: a randomized, controlled study.
Hip arthroplasty frequently requires potent postoperative analgesia, often provided with an epidural or posterior lumbar plexus local anesthetic infusion. However, American Society of Regional Anesthesia guidelines now recommend against epidural and continuous posterior lumbar plexus blocks during administration of various perioperative anticoagulants often administered after hip arthroplasty. A continuous femoral nerve block is a possible analgesic alternative, but whether it provides comparable analgesia to a continuous posterior lumbar plexus block after hip arthroplasty remains unclear. We therefore tested the hypothesis that differing the catheter insertion site (femoral versus posterior lumbar plexus) after hip arthroplasty has no impact on postoperative analgesia. ⋯ After hip arthroplasty, a continuous femoral nerve block is an acceptable analgesic alternative to a continuous posterior lumbar plexus block when using a stimulating perineural catheter. However, early ambulatory ability suffers with a femoral infusion.
-
Anesthesia and analgesia · Oct 2011
Review Historical ArticleArterial waveform analysis for the anesthesiologist: past, present, and future concepts.
Qualitative arterial waveform analysis has been in existence for millennia; quantitative arterial waveform analysis techniques, which can be traced back to Euler's work in the 18th century, have not been widely used by anesthesiologists and other clinicians. This is likely attributable, in part, to the widespread use of the sphygmomanometer, which allows the practitioner to assess arterial blood pressure without having to develop a sense for the higher-order characteristics of the arterial waveform. The 20-year delay in the development of devices that measure these traits is a testament to the primitiveness of our appreciation for this information. ⋯ The area under the peripheral arterial pressure tracing is related to stroke volume when loading conditions are stable; this finding has been used in the development of several continuous cardiac output monitors. Pulse wave velocity may be related to vascular impedance and could potentially improve the accuracy of waveform-based stroke volume estimates. Estimates of central arterial pressures (e.g., aortic) can be produced from peripheral (e.g., brachial, radial) tracings using a Generalized Transfer Function, and are incorporated into the algorithms of several continuous cardiac output monitors.