Anesthesia and analgesia
-
Anesthesia and analgesia · Aug 1992
Pipecuronium-induced neuromuscular blockade during nitrous oxide-fentanyl, enflurane, isoflurane, and halothane anesthesia in surgical patients.
This study was designed to determine the capacity of several anesthetics to augment pipecuronium neuromuscular blockade. The potency of pipecuronium was determined with single-bolus administration of 20-50 micrograms/kg in 160 patients. Patients were anesthetized with N2O/O2 (60:40) supplemented with fentanyl (4-5 micrograms/kg), halothane (0.8%), isoflurane (1.2%), or enflurane (1.7%). ⋯ Corresponding calculated doses for 50% depression of train-of-four response were significantly smaller (15.5, 14.4, 13.7, 11.9 micrograms/kg, respectively). The enhancing effects of the volatile anesthetics were reflected by significant prolongation of the clinical duration of neuromuscular blockade by pipecuronium. It is concluded that the potency of pipecuronium is enhanced more by enflurane and isoflurane than halothane or fentanyl-N2O anesthesia.
-
Anesthesia and analgesia · Jul 1992
Comparative Study Clinical Trial Controlled Clinical TrialEvaluation of the endotracheal intubating conditions of rocuronium (ORG 9426) and succinylcholine in outpatient surgery.
The time-course of action and tracheal intubating conditions of rocuronium and succinylcholine under intravenous anesthesia with propofol, alfentanil, and nitrous oxide were studied in 30 patients undergoing outpatient surgery. The neuromuscular effects of both drugs were quantified by recording the indirectly evoked twitch response of the adductor pollicis muscle after ulnar nerve stimulation (0.1 Hz, 0.2 ms supramaximal stimuli). Patients were given either 0.6 mg/kg rocuronium (n = 20) or 1 mg/kg succinylcholine (n = 10) intravenously. ⋯ The recovery of the twitch response to 25%, 75%, and 90% of its control value was shorter after succinylcholine (P less than 0.001) and occurred at 8.1 +/- 2.6, 10.3 +/- 3.9, 11.3 +/- 4.6 and 25.3 +/- 5.0, 33.1 +/- 5.9, 36.1 +/- 6.3 min after succinylcholine and rocuronium, respectively. Also the time required for spontaneous recovery from 25% to 75% of the control twitch response was significantly shorter (P less than 0.001) after succinylcholine (2.2 +/- 1.4 min) than after rocuronium (7.8 +/- 2.1 min). It is concluded that in spite of the pharmacodynamic differences between succinylcholine and rocuronium, the intubating conditions after administration of both compounds are similar and develop at the same rate.
-
Anesthesia and analgesia · Jul 1992
Randomized Controlled Trial Comparative Study Clinical TrialComparison between clonidine and epinephrine admixture to lidocaine in brachial plexus block.
The admixture of clonidine or epinephrine to lidocaine for brachial plexus block was studied with regard to duration of block, postoperative analgesia, and plasma concentrations of lidocaine. Thirty-three patients of ASA physical status I and II received an admixture of either clonidine (150 micrograms; n = 15) or epinephrine (200 micrograms; n = 18) to 40 mL of 1% lidocaine in a randomized, double-blind fashion. Bone surgery predominated in those patients receiving clonidine and soft-tissue surgery in those receiving epinephrine (P less than 0.05). ⋯ In patients who had received clonidine, peak plasma concentrations of lidocaine were higher (10.29 +/- 2.96 mumol/L) and occurred earlier (23.7 +/- 9.3 min; mean +/- SD) than in those treated with epinephrine (6.9 +/- 1.71 mumol/L; 72.5 +/- 56.2 min; P less than 0.05). This indicates the absence of a local vasoconstrictor effect of clonidine and implies a reduced margin of safety with regard to local anesthetic toxicity. Although clonidine does not offer advantages compared with epinephrine, it may be a useful adjunct to local anesthetics in those patients in whom the administration of epinephrine is contraindicated.
-
Anesthesia and analgesia · Jul 1992
Comparative StudyEfficacy of the FEF colorimetric end-tidal carbon dioxide detector in children.
Direct laryngoscopy and observation of endotracheal tube (ETT) passage between the vocal cords remain the criterion standard for verifying endotracheal intubation. Detection of end-tidal carbon dioxide (ETCO2) serves as an invaluable adjunct to confirm endotracheal intubation, detect inadvertent esophageal intubation, and monitor for accidental tracheal extubation. Capnography, however, is often unavailable outside the operating suite. ⋯ The associations among color level, infrared ETCO2 determinations, ETT size, and ETT "leak" pressures estimated by Spearman rank correlation analysis were significant only for higher infrared ETCO2 values with higher ETT leak pressures (P less than 0.05). No complications were observed. The Fenem disposable colorimetric ETCO2 detector effectively confirms clinical signs of endotracheal intubation in children when capnography is unavailable.(ABSTRACT TRUNCATED AT 250 WORDS)