Lancet
-
Although an inverse association between alcohol consumption and risk of coronary artery disease has been consistently found in several types of studies, some have argued that the association is due at least partly to the inclusion in the non-drinking reference group of men who abstain because of pre-existing disease. The association between self-reported alcohol intake and coronary disease was studied prospectively among 51,529 male health professionals. In 1986 the participants completed questionnaires about food and alcohol intake and medical history, heart disease risk factors, and dietary changes in the previous 10 years. ⋯ After adjustment for coronary risk factors, including dietary intake of cholesterol, fat, and dietary fibre, increasing alcohol intake was inversely related to coronary disease incidence (p for trend less than 0.001). Exclusion of 10,302 current non-drinkers or 16,342 men with disorders potentially related to coronary disease (eg, hypertension, diabetes, and gout) which might have led men to reduce their alcohol intake, did not substantially affect the relative risks. These findings support the hypothesis that the inverse relation between alcohol consumption and risk of coronary disease is causal.
-
Randomized Controlled Trial Clinical Trial
Prospective randomised trial of povidone-iodine, alcohol, and chlorhexidine for prevention of infection associated with central venous and arterial catheters.
More than 90% of all intravascular device-related septicaemias are due to central venous or arterial catheters. To assess the efficacy of cutaneous antisepsis to prevent catheter-associated infection, we prospectively studied three antiseptics for disinfection of patients' central venous and arterial catheter insertion sites in a surgical intensive care unit. 668 catheters were randomised to 10% povidone-iodine, 70% alcohol, or 2% aqueous chlorhexidine disinfection of the site before insertion and for site care every other day thereafter. ⋯ Of the 14 infusion-related bacteraemias (4 due to contaminated infusate or catheter hub, 10 due to infected catheters), 1 was in the chlorhexidine group and 13 were in the other two groups (odds ratio 0.16, p = 0.04). We conclude that use of 2% chlorhexidine, rather than 10% povidone-iodine or 70% alcohol, for cutaneous disinfection before insertion of an intravascular device and for post-insertion site care can substantially reduce the incidence of device-related infection.