Journal of clinical microbiology
-
J. Clin. Microbiol. · Jun 2015
Multidrug-Resistant Candida auris Misidentified as Candida haemulonii: Characterization by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry and DNA Sequencing and Its Antifungal Susceptibility Profile Variability by Vitek 2, CLSI Broth Microdilution, and Etest Method.
Candida auris is a multidrug-resistant yeast that causes a wide spectrum of infections, especially in intensive care settings. We investigated C. auris prevalence among 102 clinical isolates previously identified as Candida haemulonii or Candida famata by the Vitek 2 system. Internal transcribed spacer region (ITS) sequencing confirmed 88.2% of the isolates as C. auris, and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) easily separated all related species, viz., C. auris (n = 90), C. haemulonii (n = 6), C. haemulonii var. vulnera (n = 1), and Candida duobushaemulonii (n = 5). ⋯ Candida auris remains an unnoticed pathogen in routine microbiology laboratories, as 90% of the isolates characterized by commercial identification systems are misidentified as C. haemulonii. MALDI-TOF MS proved to be a more robust diagnostic technique for rapid identification of C. auris. Considering that misleading elevated MICs of amphotericin B by the Vitek AST-YS07 card may lead to the selection of inappropriate therapy, a cautionary approach is recommended for laboratories relying on commercial systems for identification and antifungal susceptibility testing of rare yeasts.
-
J. Clin. Microbiol. · May 2015
A new real-time reverse transcription-PCR assay for detection of human enterovirus 68 in respiratory samples.
A global reemergence of human enterovirus 68 (EV-D68) associated with severe respiratory illness occurred in 2014. We developed and validated an EV-D68-specific real-time reverse transcription-PCR (RT-PCR) for the detection of EV-D68 in respiratory samples. The rapid diagnosis of EV-D68 may contribute to better management of EV-D68 infections.
-
J. Clin. Microbiol. · May 2015
Laboratory evaluation of the Liat HIV Quant (IQuum) whole-blood and plasma HIV-1 viral load assays for point-of-care testing in South Africa.
Point-of-care (POC) HIV viral load (VL) testing offers the potential to reduce turnaround times for antiretroviral therapy monitoring, offer near-patient acute HIV diagnosis in adults, extend existing centralized VL services, screen women in labor, and prompt pediatrics to early treatment. The Liat HIV Quant plasma and whole-blood assays, prerelease version, were evaluated in South Africa. The precision, accuracy, linearity, and agreement of the Liat HIV Quant whole-blood and plasma assays were compared to those of reference technologies (Roche CAP CTMv2.0 and Abbott RealTime HIV-1) on an HIV verification plasma panel (n = 42) and HIV clinical specimens (n = 163). ⋯ Liat HIV Quant whole-blood assay would be advantageous for POC early infant diagnosis at birth and adult adherence monitoring and needs to be evaluated further in this clinical context. LIAT cartridges currently require cold storage, but the technology is user-friendly and robust. Clinical cost and implementation modeling is required.
-
The recent emergence of a severe respiratory disease caused by enterovirus D68 prompted investigation into whether Canadian hospital and provincial laboratories can detect this virus using commercial and laboratory-developed assays. This study demonstrated analytical sensitivity differences between commercial and laboratory-developed assays for the detection of enterovirus D68.
-
J. Clin. Microbiol. · Apr 2015
Evaluation of Ebola virus inactivation procedures for Plasmodium falciparum malaria diagnostics.
Plasmodium falciparum malaria is highly endemic in the three most affected countries in the current epidemic of Ebola virus disease (EVD) in West Africa. As EVD and malaria are clinically indistinguishable, both remain part of the differential diagnosis of ill travelers from returning from areas of EVD transmission. We compared the performances of a rapid diagnostic test (BinaxNOW) and real-time PCR with P. falciparum-positive specimens before and after heat and Triton X-100 inactivation, and we documented no loss of sensitivity.