The Journal of hand surgery
-
To examine the performance of the Patient-Reported Outcomes Measurement Information System (PROMIS) Upper Extremity (UE) Function Computer Adaptive Test (CAT) relative to the PROMIS Physical Function (PF) CAT in patients seeking specialty care for upper extremity conditions. ⋯ Diagnostic II.
-
The relationship between psychosocial factors and self-reported physical function among hand and upper extremity patients is complex. The Patient-Reported Outcomes Measurement Information System (PROMIS) platform has attempted to create a variety of specifically targeted metrics that can be administered using computer adaptive testing (CAT). Three metrics measuring self-reported physical function (herein referred to in combination as "functional" metrics) include the PROMIS Physical Function (PF) CAT, PROMIS Upper Extremity (UE) CAT, and the Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH). Two metrics assessing psychosocial factors include the PROMIS Anxiety and Pain Interference (PI) CATs ("nonfunctional" metrics). This study evaluates whether the functional metrics were correlated with nonfunctional metrics. ⋯ This study provides further support of the biopsychosocial model by highlighting that increased anxiety is associated with decreased self-reported function using the PROMIS platform.
-
To correlate the physical examination finding of distal radial metaphyseal tenderness with plain radiographic and magnetic resonance imaging after acute wrist injury to diagnose occult distal radius fractures. We hypothesized that persistent distal radial metaphyseal tenderness 2 weeks after acute injuries is predictive of an occult fracture. ⋯ Diagnostic III.
-
Three-dimensional planning based on computed tomography images of the malunited and the mirrored contralateral forearm allows preoperative simulations of corrective osteotomies, the fabrication of patient-specific osteotomy guides, and custom-made 3-dimensional printed titanium plates. This study aims to assess the precision and clinical outcome of this technique. ⋯ Therapeutic V.
-
Comparative Study
Biomechanical Properties of 3-Dimensional Printed Volar Locking Distal Radius Plate: Comparison With Conventional Volar Locking Plate.
This study evaluated the biomechanical properties of a new volar locking plate made by 3-dimensional printing using titanium alloy powder and 2 conventional volar locking plates under static and dynamic loading conditions that were designed to replicate those seen during fracture healing and early postoperative rehabilitation. ⋯ These results support the potential clinical utility of 3-dimensional printed volar locking plates in which design can be modified according the fracture configuration and the anatomy of the radius.