Sleep apnea-hypopnea syndrome (SAHS) is a complex public health problem causing increased risk of cardiovascular diseases. Traditionally, evaluation of the severity of the disease is based on Apnea-Hypopnea Index (AHI). It is defined as the average number of apnea and hypopnea events per hour during sleep. ⋯ For example, the correlation between AHI and the Obstruction severity-parameter was only moderate (r(2)=0.604, p<0.001). This suggests that patients with similar AHI may exhibit significantly different cardiovascular stress related to the disease. It is suggested that the present novel parameters might provide additional information over the currently used parameters and support the evaluation of the severity of SAHS.
-
Training staff in the resuscitation of neonates is an essential skill; resuscitation efficacy is difficult to quantify but critical to infant survival. Objective assessments of the efficacy of training methods, resuscitation techniques and devices have used concurrent measurements of air flow and air pressure in commercially available manikins. This system also simultaneously measures the force transmitted through the manikin head during simulated resuscitation, as applying excessive force may be deleterious to newborn infants. ⋯ This system enables comparison of staff groups, resuscitation techniques and devices in an accurate and reproducible manner. Its use could improve training by offering a means of objective performance feedback through a range of parameters. Evaluation of clinical practice may also result in direct patient benefit.
-
We have designed, built and tested an anthropomorphic-scale surrogate spinal canal, for use in preliminary evaluations of the performance characteristics of a novel intradural spinal cord stimulator. The surrogate employs a silicone mock spinal cord with semi-major and semi-minor diameters of 10 and 6 mm, respectively, commensurate with those of actual thoracic-level spinal cord. The axial restoring force provided by the 300 µm thick silicone denticulate ligament constructs on the mock cord is ~ 0.32 N mm(-1) over a 1.5 mm range of displacement, which is within a factor of 2 of that measured by others in human cadaver specimens. Examples of testing protocols of prototype intradural stimulators that employ this device are discussed.
-
We have designed, built and tested a novel device for placing intradural neurmodulator implants directly on the pial surface of the spinal cord. This applier tool is designed for ergonomic handling of delicate electro-mechanical devices such as the Iowa-Patch™ spinal cord stimulator implant, which is aimed at overcoming certain shortcomings in the performance of standard epidural stimulator devices. The applier is approximately 14 cm long, 6 mm in diameter, made of stainless steel components, and has simple and reliable mechanisms for the attachment and release of the implant from it. We describe the design of the device, details of its construction, and its performance during in vivo testing of somatosensory evoked potentials in an ovine model of intradural spinal cord stimulation.
-
The electrocardiogram (ECG) is the most widely used method for diagnosis of heart diseases, where a good quality of recordings allows the proper interpretation and identification of physiological and pathological phenomena. However, ECG recordings often have interference from noises including thermal, muscle, baseline and powerline noises. These signals severely limit ECG recording utility and, hence, have to be removed. ⋯ Therefore, the algorithm could serve as an effective framework to substantially reduce noise in ECG recordings. In addition, the resulting ECG signal distortion is notably more reduced in comparison with conventional methodologies. In summary, the current contribution introduces a new method which is able to suppress all ECG interference signals in only one step with low ECG distortion and a high noise reduction.