Hearing research
-
An estimate of lifetime noise exposure was used as the primary predictor of performance on a range of behavioral tasks: frequency and intensity difference limens, amplitude modulation detection, interaural phase discrimination, the digit triplet speech test, the co-ordinate response speech measure, an auditory localization task, a musical consonance task and a subjective report of hearing ability. One hundred and thirty-eight participants (81 females) aged 18-36 years were tested, with a wide range of self-reported noise exposure. All had normal pure-tone audiograms up to 8 kHz. ⋯ There were also no strong correlations between electrophysiological measures of synaptopathy published previously and the behavioral measures reported here. Consistent with our previous electrophysiological results, the present results provide no evidence that noise exposure is related to significant perceptual deficits in young listeners with normal audiometric hearing. It is possible that the effects of noise-induced cochlear synaptopathy are only measurable in humans with extreme noise exposures, and that these effects always co-occur with a loss of audiometric sensitivity.
-
In this study we aim to resolve the contributions of facilitation and refractoriness at very short pulse intervals. Measurements of the refractory properties of the electrically evoked compound action potential (ECAP) of the auditory nerve in cochlear implant (CI) users at inter pulse intervals below 300 μs are influenced by facilitation and recovery effects. ECAPs were recorded using masker pulses with a wide range of current levels relative to the probe pulse levels, for three suprathreshold probe levels and pulse intervals from 13 to 200 μs. ⋯ ECAPs recorded with inter pulse intervals up to 200 μs are influenced by facilitation and recovery. Facilitation effects are most pronounced for masker levels at or below ECAP threshold, while recovery effects increase with higher masker levels above ECAP threshold. The local maximum of the ECAP amplitude for masker levels around ECAP threshold can be explained by the mutual influence of maximum facilitation and minimal refractoriness.
-
Comparative Study
A comparative study of MED-EL FMT attachment to the long process of the incus in intact middle ears and its attachment to disarticulated stapes head.
The Vibrant Soundbridge© (VSB) active middle-ear implant provides an effective treatment for mild-to-severe sensorineural hearing loss in the case of normal middle ear anatomy and mixed hearing loss in middle ear malformation. The VSB floating mass transducer (FMT), with proper couplers, can be installed on various structures of the ossicular chain, e.g., the short and long process of the incus, the stapes head, and the stapes footplate. A long process (LP) coupler is most commonly used for FMT attachment to the long process of the incus with intact ossicular chain, while CliP and Bell couplers are two standardized and reliable methods for FMT attachment to the stapes head with missing incus and malleus. ⋯ Quantitatively, there was no significant difference between the CliP-FMT-coupler and Bell-FMT-coupler. According to our study, installation of CliP-FMT-coupler or Bell-FMT-coupler on the stapes head provides considerable improvement of the middle ear mechanical and functional responses, comparing with the LP-FMT-coupler in the temporal bone experiments. Moreover, the installation of the Bell-FMT-coupler to the stapes head produces essentially the same footplate velocity responses in comparison to the CliP-FMT-coupler.
-
Cochlear synaptopathy can result from various insults, including acoustic trauma, aging, ototoxicity, or chronic conductive hearing loss. For example, moderate noise exposure in mice can destroy up to ∼50% of synapses between auditory nerve fibers (ANFs) and inner hair cells (IHCs) without affecting outer hair cells (OHCs) or thresholds, because the synaptopathy occurs first in high-threshold ANFs. However, the fiber loss likely impairs temporal processing and hearing-in-noise, a classic complaint of those with sensorineural hearing loss. ⋯ A dramatic loss of synapses (mean of 50-75% in the basal half of the cochlea) was seen on IHCs surviving noise exposures that produced permanent threshold shifts (PTS) and widespread hair-cell loss. Higher noise levels were required to produce PTS in macaques compared to rodents, suggesting that primates are less vulnerable to hair-cell loss. However, the phenomenon of noise-induced cochlear synaptopathy in primates is similar to that seen in rodents.
-
Hyperacusis is a loudness hypersensitivity disorder in which moderate-intensity sounds are perceived as extremely loud, aversive and/or painful. To assess the aversive nature of sounds, we developed an Active Sound Avoidance Paradigm (ASAP) in which rats altered their place preference in a Light/Dark shuttle box in response to sound. When no sound (NS) was present, rats spent more than 95% of the time in the Dark Box versus the transparent Light Box. ⋯ However, when the 2-20 kHz or 2-8 kHz noise was presented at 60 or 90 dB SPL, the rats avoided the Dark Box significantly more than they did before the exposure, indicating these two noise bands with energy below the region of hearing loss were perceived as more aversive. In contrast, when the 16-20 kHz noise was presented at 60 or 90 dB SPL, the rats remained in the Dark Box presumably because the high-frequency hearing loss made 16-20 kHz noise less audible and less aversive. These results indicate that when rats develop a high-frequency hearing loss, they become less tolerant of low frequency noise, i.e., high intensity sounds are perceived as more aversive and should be avoided.