Cardiovascular and interventional radiology
-
Cardiovasc Intervent Radiol · Jan 2007
Influence of NaCl concentrations on coagulation, temperature, and electrical conductivity using a perfusion radiofrequency ablation system: an ex vivo experimental study.
To determine, by means of an ex vivo study, the effect of different NaCl concentrations on the extent of coagulation obtained during radiofrequency (RF) ablation performed using a digitally controlled perfusion device. ⋯ In an ex vivo model, continuous perfusion with high NaCl concentrations does not significantly improve the volume of thermal-induced coagulation. This may be because the use of a low-power generator cannot sufficiently exploit the potential advantage of better tissue conductivity provided by NaCl perfusion.
-
Cardiovasc Intervent Radiol · Nov 2006
Comparative StudyCatheter-directed thrombolysis with percutaneous rheolytic thrombectomy versus thrombolysis alone in upper and lower extremity deep vein thrombosis.
To compare the efficacy of catheter-directed thrombolysis (CDT) alone versus CDT with rheolytic percutaneous mechanical thrombectomy (PMT) for upper and lower extremity deep vein thrombosis (DVT). ⋯ Percutaneous CDT with rheolytic PMT is as effective as CDT alone for acute proximal extremity DVT but requires significantly shorter treatment duration and lower lytic doses. Randomized studies to confirm the benefits of pharmacomechanical thrombolysis in the treatment of acute proximal extremity DVT are warranted.
-
Cardiovasc Intervent Radiol · Nov 2006
Randomized Controlled TrialPercutaneous embolization of transhepatic tracks for biliary intervention.
Significant pain can occur after removing transhepatic catheters from biliary access tracks, after percutaneous biliary drainage (PBD) or stenting. We undertook a randomized prospective study to ascertain whether track embolization decreases the amount of pain or analgesic requirement after PBD. Fifty consecutive patients (M:F, 22:28; age range: 29-85 years; mean age: 66.3 years) undergoing PBD were randomized to receive track embolization or no track embolization after removal of biliary drainage catheters. ⋯ No complications were seen related to track embolization. Percutaneous track embolization after removal of biliary drainage catheters decreases patient's perception of pain and decreases the amount of required analgesia. In particular, the amount of opiate analgesia required is considerably less.
-
Cardiovasc Intervent Radiol · Nov 2006
Review Case ReportsCovered stent-graft treatment of traumatic internal carotid artery pseudoaneurysms: a review.
To review the literature concerning the management with placement of covered stent-grafts of traumatic pseudoaneurysms of the extracranial internal carotid artery (ICA) resulting from penetrating craniocervical injuries or skull base fractures. ⋯ Preliminary results suggest that placement of stent-grafts is a safe and effective method of treating ICA traumatic pseudoaneurysms resulting from penetrating craniocervical injuries or skull base fractures. The immediate results are satisfactory when the procedure takes place with appropriate anticoagulation therapy. The periprocedural morbidity and mortality and the early patency are also acceptable. A surveillance program with appropriate interventions to manage restenosis may improve the long-term patency.
-
Cardiovasc Intervent Radiol · Nov 2006
Usefulness and limitation of manual aspiration immediately after pneumothorax complicating interventional radiological procedures with the transthoracic approach.
The goal of this study was to evaluate the efficacy of simple aspiration of air from the pleural space to prevent increased pneumothorax and avoid chest tube placement in cases of pneumothorax following interventional radiological procedures performed under computed tomography fluoroscopic guidance with the transthoracic percutaneous approach. While still on the scanner table, 102 cases underwent percutaneous manual aspiration of a moderate or large pneumothorax that had developed during mediastinal, lung, and transthoracic liver biopsies and ablations of lung and hepatic tumors (independent of symptoms). Air was aspirated from the pleural space by an 18- or 20-gauge intravenous catheter attached to a three-way stopcock and 20- or 50-mL syringe. ⋯ When receiver-operating characteristic curves were applied retrospectively, the optimal cutoff level of aspirated air on which to base a decision to abandon manual aspiration alone and resort to chest tube placement was 670 mL. Percutaneous manual aspiration of the pneumothorax performed immediately after the procedure might prevent progressive pneumothorax and eliminate the need for chest tube placement. However, when the amount of aspirated air is large (such as more than 670 mL), chest tube placement should be considered.