Journal of the American College of Cardiology
-
J. Am. Coll. Cardiol. · May 1984
Electrophysiologic and hemodynamic effects of intravenous propafenone in patients with recurrent ventricular tachycardia.
Electrophysiologic and hemodynamic studies were performed before and after intravenous infusion of a new antiarrhythmic agent, propafenone, in 28 patients with recurrent ventricular tachycardia. Propafenone was given at a loading dose of 2 mg/kg in all patients. Subsequently, group A, the first 14 patients, received 1 mg/min and group B, the second 14 patients, received 2 mg/min continuous infusion. ⋯ In group B, sustained ventricular tachycardia became noninducible in three patients and nonsustained in two patients, and nonsustained ventricular tachycardia became noninducible in one patient after propafenone. Therefore, an appropriate loading dose of intravenous propafenone such as 2 mg/kg followed by 2 mg/min infusion may be given safely and may suppress ventricular tachycardia. Propafenone may be a useful addition to currently available antiarrhythmic agents.
-
J. Am. Coll. Cardiol. · Mar 1984
Comparative StudyAccurate estimates of absolute left ventricular volumes from equilibrium radionuclide angiographic count data using a simple geometric attenuation correction.
To simplify and clarify the methods of obtaining attenuation-corrected equilibrium radionuclide angiographic estimates of absolute left ventricular volumes, 27 patients who also had biplane contrast cineangiography were evaluated. Background-corrected left ventricular end-diastolic and end-systolic counts were obtained by semiautomated variable and hand-drawn regions of interest and were normalized to cardiac cycles processed, frame rate and blood sample counts. Blood sample counts were acquired on (d degree) and at a distance (d') from the collimator. ⋯ Using the blood sample counts obtained at d degree or d', the attenuation-corrected radionuclide left ventricular end-systolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-systolic volumes (r = 0.96 to 0.98). Also, using blood sample counts at d degree, the mean radionuclide semiautomated variable left ventricular end-systolic volume (116 +/- 98 ml, p less than 0.05) was less than the average cineangiographic end-systolic volume (128 +/- 98 ml), and the other radionuclide end-systolic volumes did not differ from the average cineangiographic end-systolic volume. Therefore, it is concluded that: 1) a simple geometric attenuation-correction of radionuclide left ventricular end-diastolic and end-systolic count data provides accurate estimates of biplane cineangiographic end-diastolic and end-systolic volumes; and 2) the hand-drawn region of interest selection method, unlike the semiautomated variable method that underestimates end-diastolic and end-systolic volumes, provides more accurate estimates of biplane cineangiographic left ventricular volumes irrespective of the distance blood sample counts are acquired from the collimator.
-
J. Am. Coll. Cardiol. · Nov 1983
Definition of the safe lower limits of aortic resection during surgical procedures on the thoracoabdominal aorta: use of somatosensory evoked potentials.
The technique of intraoperative monitoring of somatosensory evoked potentials was applied to a canine model of spinal cord ischemia in an attempt to determine the safe lower limits of aortic resection during thoracic aortic surgery. Fifteen animals underwent left thoracotomy with institution of partial left atrial/femoral artery bypass for maintenance of distal aortic perfusion after proximal descending thoracic aortic exclusion. In Group I animals (n = 6, control), no further interventions were performed so that the effect of exclusion of vessels noncritical to spinal cord blood supply could be assessed by measurements of spinal cord blood flow and somatosensory evoked potentials. ⋯ The effect of critical vessel exclusion on spinal cord blood flow was then assessed. Exclusion of multiple vessels noncritical to spinal cord blood supply (Group I) had no effect on spinal cord blood flow or function (somatosensory evoked potentials). Exclusion of vessels critical to spinal cord blood supply resulted in significant spinal cord ischemia (83.4% flow reduction, probability [p] less than 0.05 versus baseline) and ischemic spinal cord dysfunction (loss of somatosensory evoked potential).(ABSTRACT TRUNCATED AT 250 WORDS)
-
J. Am. Coll. Cardiol. · Nov 1983
Comparative StudyTwo-dimensional echocardiographic estimation of right ventricular ejection fraction in patients with coronary artery disease.
Two-dimensional echocardiographic determination of right ventricular ejection fraction was compared with right ventricular ejection fraction obtained by first pass radionuclide angiography in 39 patients with coronary artery disease. Apical four chamber and two chamber right ventricular views were obtained in 34 (87%) of the 39 patients, while a subcostal four chamber view was obtained in 31 patients (80%). Right ventricular ejection fraction by two-dimensional echocardiography was calculated by the biplane area-length and Simpson's rule methods using two paired orthogonal views and utilizing a computerized light-pen method for tracing the right ventricular endocardium. ⋯ There were no differences in right ventricular ejection fraction between patients with acute and old inferior myocardial infarction by both techniques. No correlation was found between left and right ventricular ejection fraction by radionuclide angiography (r = 0.16). It is concluded that 1) right ventricular ejection fraction by two-dimensional echocardiography correlates well with radionuclide angiographic measurements and can reliably evaluate right ventricular function in coronary artery disease, 2) patients with inferior myocardial infarction have reduced right ventricular ejection fraction, and 3) changes in left ventricular ejection fraction do not directly influence right ventricular function.
-
J. Am. Coll. Cardiol. · Oct 1983
Case ReportsRight to left shunt, with severe hypoxemia, at the atrial level in a patient with hemodynamically important right ventricular infarction.
This report describes a patient with a massive right ventricular infarction, complicated by severe hypoxemia. Contrast echocardiography demonstrated a right to left shunt through a previously asymptomatic atrial septal defect. This phenomenon should be considered as a possible cause of hypoxemia in the presence of right ventricular infarction.