Insufficient oxygenation, ventilation and gastric inflation with subsequent regurgitation of stomach contents is a major hazard of bag-valve-face mask ventilation during the basic life support phase of cardiopulmonary resuscitation (CPR). The European Resuscitation Council has recommended smaller tidal volumes of approximately 500 ml as an effort to reduce gastric inflation; furthermore, the intubating laryngeal mask airway and the laryngeal tube have been recently developed in order to provide rapid ventilation and to secure the airway. The purpose of our study was to examine whether usage of a newly developed medium-size self-inflating bag (maximum volume, 1100 ml) in association with the intubating laryngeal mask airway, and laryngeal tube may provide adequate lung ventilation, while reducing the risk of gastric inflation in a bench model simulating the initial phase of CPR. ⋯ M. lung tidal volumes (605+/-22 vs. 832+/-4 ml, and 666+/-27 vs. 887+/-37 ml, respectively), but comparable peak airway pressures. No gastric inflation occurred when using both devices with either ventilation bag. In conclusion, both the intubating laryngeal mask airway and laryngeal tube in combination with both an 1100 and 1500 ml maximum volume self inflating bag proved to be valid alternatives for emergency airway management in a bench model of a simulated unintubated cardiac arrest victim.
-
Chest compressions before initial defibrillation attempts have been shown to increase successful defibrillation. This animal study was designed to assess whether ventricular fibrillation mean frequency after 90 s of basic life support cardiopulmonary resuscitation (CPR) may be used as an indicator of coronary perfusion and mean arterial pressure during CPR. ⋯ In this porcine laboratory model, 90 s and 3 min of CPR improved ventricular fibrillation mean frequency, which correlated positively with coronary perfusion pressure, and mean arterial pressure.
-
In Singapore, all public emergency ambulances are equipped with semi-automatic external defibrillators and the crew is trained in their use. This is the first paper from Singapore reporting the survival rate in patients presenting to an urban public hospital with acute coronary syndrome (ACS) who developed out-of-hospital cardiac arrest (OHCA). All consecutive patients who presented to the ED of a public hospital with OHCA or ACS were surveyed from 1 April 1999 to 30 September 1999. ⋯ Twenty (17.4%) of the OHCA patients had return of spontaneous circulation after resuscitation in the ED. Four patients (3.5%), all with an initial rhythm of VF were discharged alive from the hospital. Much remains to be done to reduce the time interval to first DC shock for the OHCA group.
-
In trauma management, the importance of early and effective control of the airway is acknowledged universally. Attention to the airway is particularly vital when a casualty has sustained serious head or facial injuries. ⋯ A case is described in which the intubating laryngeal mask airway (ILMA or LMA-Fastrach) was used successfully in the pre-hospital setting to secure the airway of a patient who had sustained serious head and facial injuries in a road traffic collision. The indications for the use of the ILMA in pre-hospital care are discussed.
-
Electrode polarity may alter the success of biphasic shocks from implantable systems. Whether the electrode polarity influences the success of transthoracic biphasic defibrillation is unknown. We determined the effect of electrode polarity on biphasic transthoracic defibrillation in a porcine model. ⋯ In this porcine model of transthoracic defibrillation, varying the biphasic shock electrode polarity did not alter transthoracic defibrillation success. Positional labeling of transthoracic biphasic defibrillation electrode pads may be unnecessary.