Intra- and extravascular volume status in patients undergoing mitral valve replacement: crystalloid vs. colloid priming of cardiopulmonary bypass.
Cardiopulmonary bypass is associated with changes of intra- and extravascular volume status often resulting in cardiopulmonary dysfunction. The purpose of this prospective double-blind study was to evaluate the influence of different priming solutions of the extracorporeal circuit on intra- and extravascular volume status and haemodynamics in patients undergoing elective mitral valve replacement. ⋯ The use of colloid priming solutions in patients with mitral valve insufficiency leads to less fluid requirements and significantly reduced fluid shift in the interstitium. However, these changes are not associated with changes in haemodynamic parameters or short term outcome.
-
The reasons for coagulopathy may be multiple and the identification of the underlying cause is often difficult. Recently, we identified two patients showing characteristics of heparin overdose during surgery. We hypothesised that filling a Shaldon dialysis catheter with heparin prior to closure, so-called heparin lock, might have triggered this coagulation disorder. Therefore, the aim of this in vitro study was to show whether this procedure can lead to an iatrogenic administration of heparin. ⋯ Following a heparin lock a considerable amount of the injected solution is accidentally administered to the patient. Only 49.1% of the injected volume may remain in the Shaldon catheter. This could lead to an increased risk of coagulopathy.
-
Comparative Study
Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model.
Despite the introduction of various less-invasive concepts of cardiac output measurement, pulmonary arterial thermodilution is still the most common measurement technique. ⋯ Our data suggest that pulmonary arterial thermodilution and PiCCO may be interchangeably used for cardiac output measurement even under acute haemodynamic changes. The method described by Bland and Altman demonstrated an overestimation of cardiac output for both thermodilution methods. HemoSonic and NICO offer non-invasive alternatives and complementary monitoring tools in numerous clinical situations. Trend monitoring and haemodynamic optimizing can be applied sufficiently, when absolute measures are judged critically in a clinical context. The use of the NICO system seems to be limited during acute circulatory changes.
-
To determine the minimal oxygen delivery and pump flow that can maintain systemic oxygen uptake during normothermic (37 degrees C) pulsatile and non-pulsatile cardiopulmonary bypass in dogs. ⋯ Oxygen delivery values greater than 7-8 mL min(-1) kg(-1) were required to maintain oxygen uptake during normothermic cardiopulmonary bypass with either pulsatile or non-pulsatile blood flow. Elevation of blood lactate levels during bypass helps to identify inadequate tissue oxygen delivery related to insufficient pump flow.