Journal of applied physiology
-
Hypotension and shock are risk factors for death, renal insufficiency, and stroke in preterm neonates. Goal-directed neonatal hemodynamic management lacks end-organ monitoring strategies to assess the adequacy of perfusion. Our aim is to develop a clinically viable, continuous metric of renovascular reactivity to gauge renal perfusion during shock. ⋯ The RVx compared favorably to the renal laser-Doppler data. Areas under the receiver operator characteristic curves using renal blood flow thresholds of 50% and 25% of baseline were 0.85 (95% CI, 0.83-0.87) and 0.90 (95% CI, 0.88-0.92). Renovascular autoregulation can be monitored and is impaired in advance of cerebrovascular autoregulation during hemorrhagic shock.